English
Language : 

XB1004-BD Datasheet, PDF (9/12 Pages) Mimix Broadband – 16.0-30.0 GHz GaAs MMIC Buffer Amplifier
XB1004-BD
Buffer Amplifier
16.0-30.0 GHz
Rev. V1
MTTF Tables
These numbers were calculated based on accelerated life test information and thermal model analysis received from the fabricating
foundry.
Backplate Temperature Channel Temperature
55 deg Celsius
83.4 deg Celsius
75 deg Celsius
105.5 deg Celsius
95 deg Celsius
127.4 deg Celsius
Bias Conditions: Vd1=Vd2=4.0V, Id1=45 mA, Id2=45 mA
Rth
78.8° C/W
84.7° C/W
90.0° C/W
MTTF Hours
5.36E+10
3.52E+09
3.206E+08
FITs
1.87E-02
2.84E-01
3.13E+00
Backplate Temperature Channel Temperature
55 deg Celsius
108.3 deg Celsius
75 deg Celsius
132.1 deg Celsius
95 deg Celsius
155.5 deg Celsius
Bias Conditions: Vd1=Vd2=5.0V, Id1=70 mA, Id2=70 mA
Rth
76.1° C/W
81.5° C/W
86.4° C/W
MTTF Hours
2.56E+09
1.992E+08
2.12E+07
FITs
3.91E-01
5.04E+00
4.72E+01
Backplate Temperature Channel Temperature
55 deg Celsius
138.1 deg Celsius
75 deg Celsius
163.7 deg Celsius
95 deg Celsius
188.8 deg Celsius
Bias Conditions: Vd1=Vd2=6.0V, Id1=90 mA, Id2=90 mA
Rth
77.0° C/W
82.1° C/W
86.8° C/W
MTTF Hours
1.08E+08
1.02E+07
1.29E+06
FITs
9.22E-00
9.82E+01
7.73E+02
9
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
• India Tel: +91.80.43537383
• China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.