English
Language : 

LAFL-C2-0350 Datasheet, PDF (8/25 Pages) Lumileds Lighting Company – Automotive Forward Lighting Source
Typical Electrical Characteristics at Temperature Extremes
Table 3.
Typical Condition Typical Condition
1000 mA DC Operation 1000 mA DC Operation
Form Case Temperature TC = - 40°C Case Temperature TC = 130°C
Factor Forward Voltage Vf [1] Forward Voltage Vf [1]
(V) (V)
Min.
Typical
Max.
Min.
Typical
Max.
1x2
5.6
6.8
7.9
5.0
5.9
7.3
1x4
11.2
13.2
15.8
10.0
11.8
14.5
Notes for Table 3:
1. Philips Lumileds tests forward voltage values via a pulsed measurement at junction temperature of 25°C. Typical product performance at
maximum and minimum allowable case temperature to allow for electronic driver design. Values provided are guard banded to ensure that
minimum and maximum values are not exceeded under stated use conditions.
LUXEON Altilon Datasheet DS66 20130320
8