DS56 Datasheet, PDF (5/33 Pages) Dallas Semiconductor – Dual Temperature Comparator
Color
Red
Flux Characteristics for LUXEON Rebel Continued
Thermal Pad Temperature = 25°C
Table 1. Continued
Performance at Test Current
Typical Performance
at Indicated Current
Part Number
Minimum Luminous
Flux (lm)
Φ [1] [3]
V
Test
Current
(mA)
Typical Luminous
Flux (lm)
Φ [2] [3]
V
Drive
Current
(mA)
LXML PD01 0030
30
350
LXML PD01 0040
40
350
65
700
85
700
Red
LXML PH01 0040
40
350
Orange
LXML PH01 0050
50
350
85
700
100
700
Amber
LXML PL01 0023
23.5
350
LXML PL01 0030
30.0
350
50
700
65
700
Notes for Table 1:
1. Minimum luminous flux or radiometric power performance guaranteed within published operating conditions. Philips
Lumileds maintains a tolerance of ± 6.5% on flux and power measurements.
2. Typical luminous flux performance is when device is operated within published operating conditions.
3. LUXEON Rebel products with even higher luminous flux and levels will become available in the future. Please consult
Philips Lumileds or Future Electronics for more information.
LUXEON Rebel Datasheet DS56 (7/07)
5