English
Language : 

LTC4007_1 Datasheet, PDF (4/24 Pages) Linear Technology – 4A, High Efficiency, Standalone Li-Ion Battery Charger
LTC4007
ELECTRICAL CHARACTERISTICS The ● denotes specifications which apply over the full operating
temperature range (Note 4), otherwise specifications are at TA = 25°C. VDCIN = 20V, VBAT = 12V unless otherwise noted.
SYMBOL PARAMETER
CONDITIONS
MIN TYP MAX
VOL
Low Logic Level of ACP, CHG, FLAG, LOBAT,
IOL = 100µA
ICL, FAULT
VOH
High Logic Level of CHG, LOBAT, ICL
IOH = –1µA
IOFF
Off State Leakage Current of ACP, FLAG, FAULT VOH = 3V
IPO
Pull-Up Current on CHG, LOBAT, ICL
V = 0V
Timer Defeat Threshold at CHG
●
0.5
● 2.7
–1
1
– 10
1
Programming Inputs (CHEM and 3C4C)
VIH
VIL
IPI
Oscillator
High Logic Level
Low Logic Level
Pull-Up Current
V = 0V
●
●1
3.3
– 14
fOSC
Regulator Switching Frequency
fMIN
Regulator Switching Frequency in Drop Out
DCMAX Regulator Maximum Duty Cycle
Gate Drivers (TGATE, BGATE)
Duty Cycle ≥ 98%
VCSP = VBAT
255
300
345
20
25
98
99
TGTR
TGTF
BGTR
BGTF
VTGATE High (VCLN – VTGATE)
VBGATE High
VTGATE Low (VCLN – VTGATE)
VBGATE Low
TGATE Transition Time
TGATE Rise Time
TGATE Fall Time
BGATE Transition Time
BGATE Rise Time
BGATE Fall Time
VTGATE at Shutdown (VCLN – VTGATE)
VBGATE at Shutdown
ITGATE = –1mA
CLOAD = 3000pF
CLOAD = 3000pF
IBGATE = 1mA
CLOAD = 3000pF, 10% to 90%
CLOAD = 3000pF, 10% to 90%
CLOAD = 3000pF, 10% to 90%
CLOAD = 3000pF, 10% to 90%
ITGATE = –1µA, DCIN = 0V, CLN = 12V
IBGATE = 1µA, DCIN = 0V, CLN = 12V
50
4.5
5.6
10
4.5
5.6
10
50
50
110
50
100
40
90
40
80
100
100
UNITS
V
V
µA
µA
V
V
V
µA
kHz
kHz
%
mV
V
V
mV
ns
ns
ns
ns
mV
mV
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: See Test Circuit.
Note 3: Does not include tolerance of current sense resistor or current
programming resistor.
Note 4: The LTC4007E is guaranteed to meet performance specifications
from 0°C to 70°C. Specifications over the –40°C to 85°C operating
temperature range are assured by design, characterization and correlation
with statistical process controls.
4007fa
4