English
Language : 

LTC4011_15 Datasheet, PDF (3/26 Pages) Linear Technology – High Efficiency Standalone Nickel Battery Charger
LTC4011
Electrical Characteristics The l indicates specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. VCC = 12V, BAT = 4.8V, GND = PGND = 0V, unless otherwise noted.
SYMBOL PARAMETER
CONDITIONS
MIN
TYP
MAX UNITS
Thermistor Termination
VRT
Output Voltage
RL = 10k
3.075
3.3
3.525
V
l
3
3.6
V
IRT
Short-Circuit Current
VRT = 0V
l
–9
–1
mA
PWM Current Source
VFS
BAT – SENSE Full-Scale Regulation
Voltage (Fast Charge)
0.3V < BAT < VCC – 0.3V (Note 5)
BAT = 4.8V
95
l
95
100
105
mV
100
105
mV
VPC
BAT – SENSE Precharge Regulation Voltage 0.3V < BAT < VCC – 0.3V (Note 5)
16
20
24
mV
BAT = 4.8V
l
16
20
24
mV
VTC
BAT – SENSE Top-Off Charge
Regulation Voltage
0.3V < BAT < VCC – 0.3V (Note 5)
BAT = 4.8V
6.5
l
6.5
10
13.5
mV
10
13.5
mV
∆VLI
IBAT
ISENSE
IOFF
fTYP
fMIN
DCMAX
VOL(TG)
VOH(TG)
tR(TG)
tF(TG)
VOL(BG)
VOH(BG)
tR(BG)
tF(BG)
BAT – SENSE Line Regulation
BAT Input Bias Current
SENSE Input Bias Current
Input Bias Current
Typical Switching Frequency
Minimum Switching Frequency
Maximum Duty Cycle
TGATE Output Voltage Low
(VCC – TGATE, Note 7)
TGATE Output Voltage High
TGATE Rise Time
TGATE Fall Time
BGATE Output Voltage Low
BGATE Output Voltage High
BGATE Rise Time
BGATE Fall Time
5.5V < VCC < 25V, Fast Charge
0.3V < BAT < VCC – 0.1V
SENSE = BAT
SENSE or BAT, VCELL = 0V
VCC > 9V, No Load
VCC < 7V, No Load
VCC – TGATE, No Load
CLOAD = 3nF, 10% to 90%
CLOAD = 3nF, 10% to 90%
No Load
No Load
CLOAD = 1.6nF, 10% to 90%
CLOAD = 1.6nF, 10% to 90%
±0.3
mV
–2
2
mA
50
150
µA
l
–1
0
1
µA
l
460
550
640
kHz
l
20
30
kHz
98
99
%
l
5
5.6
8.75
V
l VCC – 0.5
VCC
V
l
0
50
mV
35
100
ns
45
100
ns
l
0
50
mV
l INTVDD – 0.075 INTVDD
V
35
80
ns
15
80
ns
ADC Inputs
ILEAK
Analog Channel Leakage
0V < VCELL < 2V, 550mV < VTEMP < 2V
±100
nA
Charger Thresholds
VBP
VBOV
VMFC
VFCBF
∆VTERM
Battery Present Threshold Voltage
Battery Overvoltage
Minimum Fast Charge Voltage
Fast Charge Battery Fault Voltage
–∆V Termination
CHEM OPEN (NiCd)
CHEM = 0V (NiMH)
l
320
350
370
mV
l 1.815
1.95
2.085
V
l
850
900
950
mV
l 1.17
1.22
1.27
V
l
16
20
25
mV
l
6
10
14
mV
VAR
∆TTERM
Automatic Recharge Voltage
∆T Termination (Note 8)
VCELL Decreasing
CHEM = 3.3V (NiCd)
CHEM = 0V (NiMH)
l 1.260
l
1.3
l
0.5
1.325
2
1
1.390
2.7
1.5
V
°C/min
°C/min
TMIN
Minimum Charging Temperature (Note 8) VTEMP Increasing
l
0
5
9
°C
TMAXI
Maximum Charge Initiation
Temperature (Note 8)
VTEMP Decreasing, Not Charging
l 41.5
45
47
°C
4011fb