Applications Information
FROM
ADAPTER
12V
INFET
FAULT
CHRG
TOC
READY
10µF
10µH
LTC4011
FROM
ADAPTER
12V
10µF
0.1µF
Figure 6. Minimum 1A LTC4011 Application
20µF
FAULT
CHRG
TOC
READY
4.7µH
0.1µF
0.033µF
20µF
0.068µF
Figure 7. 3A NiMH Charger with Full PowerPath Control
A full-featured 2A LTC4011 application is shown in Figure 8.
FET-based PowerPath allows for maximum input voltage
range from the DC adapter. The inherent voltage ratings
of the VCELL, VCDIV, SENSE and BAT pins allow charging
of one to sixteen series nickel cells in this application,
governed only by the VCC overhead limits previously dis-
cussed. The application includes all average cell voltage
and battery temperature sensing circuitry required for the
LTC4011 to utilize its full range of charge qualification,
safety monitoring and fast charge termination features.
LED D1 indicates valid DC input voltage and installed
battery, while LEDs D2 and D3 indicate charging. LED D4
indicates fault conditions. The grounded CHEM pin selects
the NiMH charge termination parameter set.
4011fb
19