APPLICATIONS INFORMATION
Tracking and Soft-Start (TRACK/SS Pins)
The start-up of each VOUT is controlled by the voltage on
the respective TRACK/SS pin. When the voltage on the
TRACK/SS pin is less than the internal 0.8V reference, the
LTC3857-1 regulates the VFB pin voltage to the voltage on
the TRACK/SS pin instead of 0.8V. The TRACK/SS pin can
be used to program an external soft-start function or to
allow VOUT to track another supply during start-up.
Soft-start is enabled by simply connecting a capacitor
from the TRACK/SS pin to ground, as shown in Figure 6.
An internal 1μA current source charges the capacitor,
providing a linear ramping voltage at the TRACK/SS pin.
The LTC3857-1 will regulate the VFB pin (and hence VOUT)
according to the voltage on the TRACK/SS pin, allowing
VOUT to rise smoothly from 0V to its final regulated value.
The total soft-start time will be approximately:
tSS
=
CSS
•
0.8V
1μA
1/2 LTC3857-1
TRACK/SS
CSS
SGND
38571 F06
Figure 6. Using the TRACK/SS Pin to Program Soft-Start
Alternatively, the TRACK/SS pin can be used to track two
(or more) supplies during start-up, as shown qualitatively
in Figures 7a and 7b. To do this, a resistor divider should
be connected from the master supply (VX) to the TRACK/
SS pin of the slave supply (VOUT), as shown in Figure 8.
During start-up VOUT will track VX according to the ratio
set by the resistor divider:
VX = RA • RTRACKA + RTRACKB
VOUT RTRACKA
RA + RB
For coincident tracking (VOUT = VX during start-up):
RA = RTRACKA
RB = RTRACKB
VX(MASTER)
VOUT(SLAVE)
TIME
38571 F07a
(7a) Coincident Tracking
VX(MASTER)
VOUT(SLAVE)
TIME
38571 F07b
(7b) Ratiometric Tracking
Figure 7. Two Different Modes of Output Voltage Tracking
Vx VOUT
RTRACKB
RTRACKA
RB 1/2 LTC3857-1
VFB
RA
TRACK/SS
38571 F08
Figure 8. Using the TRACK/SS Pin for Tracking
38571fc