English
Language : 

LTC3736_15 Datasheet, PDF (19/28 Pages) Linear Technology – Dual 2-Phase, No RSENSE, Synchronous Controller with Output Tracking
APPLICATIO S I FOR ATIO
VOUT1
VOUT2
LTC3736
VOUT1
VOUT2
TIME
(7b) Coincident Tracking
TIME
3736 F07b,c
(7c) Ratiometric Tracking
Figures 7b and 7c. Two Different Modes of Output Voltage Tracking
For coincident tracking (VOUT1 = VOUT2 during start-up),
R2A = RTRACKA
R2B = RTRACKB
The ramp time for VOUT2 to rise from 0V to its final value
is:
tSS2
=
tSS1
•
RTRACKA
R1A
•
R1A + R1B
RTRACKA + RTRACKB
For coincident tracking,
tSS2
=
tSS1
•
VOUT2F
VOUT1F
where VOUT1F and VOUT2F are the final, regulated values of
VOUT1 and VOUT2. VOUT1 should always be greater than
VOUT2 when using the TRACK pin. If no tracking function
is desired, then the TRACK pin may be tied to VIN. How-
ever, in this situation there would be no (internal nor
external) soft-start on VOUT2.
Phase-Locked Loop and Frequency Synchronization
The LTC3736 has a phase-locked loop (PLL) comprised
of an internal voltage-controlled oscillator (VCO) and a
phase detector. This allows the turn-on of the external P-
channel MOSFET of controller 1 to be locked to the rising
edge of an external clock signal applied to the SYNC/FCB
pin. The turn-on of controller 2’s external P-channel
MOSFET is thus 180 degrees out of phase with the
external clock. The phase detector is an edge sensitive
digital type that provides zero degrees phase shift
between the external and internal oscillators. This type of
phase detector does not exhibit false lock to harmonics of
the external clock.
The output of the phase detector is a pair of complemen-
tary current sources that charge or discharge the external
filter network connected to the PLLLPF pin. The relation-
ship between the voltage on the PLLLPF pin and operating
frequency, when there is a clock signal applied to SYNC/
FCB, is shown in Figure 8 and specified in the Electrical
Characteristics table. Note that the LTC3736 can only be
synchronized to an external clock whose frequency is
within range of the LTC3736’s internal VCO, which is
nominally 200kHz to 1MHz. This is guaranteed, over
temperature and variations, to be between 300kHz and
750kHz. A simplified block diagram is shown in Figure 9.
1400
1200
1000
800
600
400
200
0
0
0.5
1
1.5
2 2.4
PLLLPF PIN VOLTAGE (V)
3736 F08
Figure 8. Relationship Between Oscillator Frequency and Voltage
at the PLLLPF Pin When Synchronizing to an External Clock
3736fa