OPERATION (Refer to the Functional Diagram)
LTC3890-2
5V SWITCH
20V/DIV
3.3V SWITCH
20V/DIV
INPUT CURRENT
5A/DIV
INPUT VOLTAGE
500mV/DIV
IIN(MEAS) = 2.53ARMS
IIN(MEAS) = 1.55ARMS
38902 F01
Figure 1. Input Waveforms Comparing Single-Phase (a) and 2-Phase (b) Operation for Dual Switching Regulators
Converting 12V to 5V and 3.3V at 3A Each. The Reduced Input Ripple with the 2-Phase Regulator Allows
Less Expensive Input Capacitors, Reduces Shielding Requirements for EMI and Improves Efficiency
With 2-phase operation, the two channels of the dual
switching regulator are operated 180 degrees out-of-phase.
This effectively interleaves the current pulses drawn by the
switches, greatly reducing the overlap time where they add
together. The result is a significant reduction in total RMS
input current, which in turn allows less expensive input
capacitors to be used, reduces shielding requirements for
EMI and improves real world operating efficiency.
Figure 1 compares the input waveforms for a representative
single-phase dual switching regulator to the LTC3890-2
2-phase dual switching regulator. An actual measurement of
the RMS input current under these conditions shows that
2-phase operation dropped the input current from 2.53ARMS
to 1.55ARMS. While this is an impressive reduction in itself,
remember that the power losses are proportional to IRMS2,
meaning that the actual power wasted is reduced by a fac-
tor of 2.66. The reduced input ripple voltage also means
less power is lost in the input power path, which could
include batteries, switches, trace/connector resistances
and protection circuitry. Improvements in both conducted
and radiated EMI also directly accrue as a result of the
reduced RMS input current and voltage.
Of course, the improvement afforded by 2-phase opera-
tion is a function of the dual switching regulator’s relative
duty cycles which, in turn, are dependent upon the input
voltage VIN (Duty Cycle = VOUT/VIN). Figure 2 shows how
the RMS input current varies for single-phase and 2-phase
operation for 3.3V and 5V regulators over a wide input
voltage range.
It can readily be seen that the advantages of 2-phase op-
eration are not just limited to a narrow operating range,
for most applications is that 2-phase operation will reduce
the input capacitor requirement to that for just one chan-
nel operating at maximum current and 50% duty cycle.
3.0
SINGLE PHASE
2.5
DUAL CONTROLLER
2.0
1.5
2-PHASE
DUAL CONTROLLER
1.0
0.5 VO1 = 5V/3A
VO2 = 3.3V/3A
0
0
10
20
30
INPUT VOLTAGE (V)
40
38902 F02
Figure 2. RMS Input Current Comparison
38902f