LTC3566-2_15 Datasheet, PDF (15/28 Pages) Linear Technology – High Efficiency USB Power Manager Plus 1A Buck-Boost Converter
LTC3566/LTC3566-2
OPERATION
Battery Charger
The LTC3566 family includes a constant-current/constant-
voltage battery charger with automatic recharge, automatic
termination by safety timer, low voltage trickle charging,
bad cell detection and thermistor sensor input for out-of-
temperature charge pausing.
Battery Preconditioning
When a battery charge cycle begins, the battery charger
first determines if the battery is deeply discharged. If the
battery voltage is below VTRKL, typically 2.85V, an automatic
trickle charge feature sets the battery charge current to
10% of the programmed value. If the low voltage persists
for more than 1/2 hour, the battery charger automatically
terminates and indicates via the CHRG pin that the battery
was unresponsive.
Once the battery voltage is above 2.85V, the battery charger
begins charging in full power constant-current mode. The
current delivered to the battery will try to reach 1022V/
RPROG. Depending on available input power and external
load conditions, the battery charger may or may not be
able to charge at the full programmed rate. The external
load will always be prioritized over the battery charge
current. The USB current limit programming will always
be observed and only additional power will be available to
charge the battery. When system loads are light, battery
charge current will be maximized.
Charge Termination
The battery charger has a built-in safety timer. When
the voltage on the battery reaches the pre-programmed
float voltage of 4.200V, the battery charger will regulate
the battery voltage and the charge current will decrease
naturally. Once the battery charger detects that the battery
has reached 4.200V, the four hour safety timer is started.
After the safety timer expires, charging of the battery will
discontinue and no more current will be delivered.
Automatic Recharge
After the battery charger terminates, it will remain off
drawing only microamperes of current from the battery.
If the portable product remains in this state long enough,
the battery will eventually self discharge. To ensure that
the battery is always topped off, a charge cycle will au-
tomatically begin when the battery voltage falls below
4.1V. In the event that the safety timer is running when
the battery voltage falls below 4.1V, it will reset back to
zero. To prevent brief excursions below 4.1V from reset-
ting the safety timer, the battery voltage must be below
4.1V for more than 1.3ms. The charge cycle and safety
timer will also restart if the VBUS UVLO cycles low and
then high (e.g. VBUS, is removed and then replaced) or if
the battery charger is cycled on and off by the CHRGEN
digital I/O pin.
Charge Current
The charge current is programmed using a single resis-
tor from PROG to ground. 1/1022th of the battery charge
current is sent to PROG which will attempt to servo to
1.000V. Thus, the battery charge current will try to reach
1022 times the current in the PROG pin. The program
resistor and the charge current are calculated using the
following equations:
RPROG
=
1022V
ICHG
, ICHG
=
1022V
RPROG
In either the constant-current or constant-voltage charging
modes, the voltage at the PROG pin will be proportional to
the actual charge current delivered to the battery. There-
fore, the actual charge current can be determined at any
time by monitoring the PROG pin voltage and using the
following equation:
IBAT
=
VPROG
RPROG
•
1022
In many cases, the actual battery charge current, IBAT, will
be lower than ICHG due to limited input power available and
prioritization with the system load drawn from VOUT.
Charge Status Indication
The CHRG pin indicates the status of the battery charger.
Four possible states are represented by CHRG which
include charging, not charging, unresponsive battery and
battery temperature out of range.
3566fb
15