English
Language : 

HC010A0F1-S Datasheet, PDF (2/19 Pages) Lineage Power Corporation – 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current
Data Sheet
May 16, 2008
HC006/010 Series DC-DC Power Module:
18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
I/O Isolation Voltage (100% factory tested)
Device
Symbol
Min
All
VIN
-0.3
All
TA
-40
All
Tstg
-55
All
⎯
⎯
Max
50
85
125
1500
Unit
Vdc
°C
°C
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(VIN=0V to 75V, IO=IO, max)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN=0V to
75V, IO= IOmax ; see Figure 9)
Input Ripple Rejection (120Hz)
EMC, EN55022
Device
HC
HC
All
All
All
Symbol Min
Typ
Max
Unit
VIN
18
24
36
Vdc
IIN,max
3.2
Adc
I2t
1
A2s
3
mAp-p
50
dB
See EMC Considerations section
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 5A (see Safety Considerations section). Based on the information
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating
can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE POWER
2