HC010A0F1-S Datasheet, PDF (1/19 Pages) Lineage Power Corporation – 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current | |||
|
Data Sheet
May 16, 2008
HC006/010 Series DC-DC Converter Power Modules:
18-36Vdc Input; 3.3V-5Vdc Output; 6.6A-10A Output Current
RoHS Compliant
Features
 Compliant to RoHS EU Directive 2002/95/EC (-Z
versions)
 Compliant to ROHS EU Directive 2002/95/EC with
lead solder exemption (non-Z versions)
 Delivers up to 10A Output current
Applications
 Wireless Networks
 Distributed power architectures
 Optical and Access Network Equipment
 Enterprise Networks
 Latest generation ICâs (DSP, FPGA, ASIC)
and Microprocessor powered applications
Options
 Remote On/Off logic (positive or negative)
 Surface Mount (-S Suffix)
 Trimmed leads
5V (6.6A), 3.3V (10A)
 High efficiency â 90% at 3.3V full load
 Low Output voltage- supports migration to future IC
supply voltages down to 1.0V
 Low output ripple and noise
 Small Size and low profile
47.2mm x 29.5mm x 8.5mm
(1.86 x 1.16 x 0.335 in)
 Surface mount or Through hole (TH)
 Remote On/Off
 Output overcurrent/Over voltage protection
 Over temperature protection
 Single Tightly regulated output
 Output voltage adjustment trim ±10%
 Wide operating temperature range (-40°C to 85°C)
 Meets the voltage insulation requirements for ETSI
300-132-2 and complies with and is Licensed for
Basic Insulation rating per EN 60950
 CE mark meets 73/23/EEC and 93/68/EEC
directives§
 UL* 60950-1Recognized, CSAâ C22.2 No. 60950-1-
03 Certified, and VDEâ¡ 0805:2001-12 (EN60950-1)
Licensed
 ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
The HC series power modules are isolated dc-dc converters that operate over a wide input voltage range of 18 to 36
Vdc and provide one precisely regulated output. The output is fully isolated from the input, allowing versatile polarity
configurations and grounding connections. The modules exhibit high efficiency, e.g. typical efficiency of 90%
3.3/10A, 91% at 5V/6A. Built-in filtering for both input and output minimizes the need for external filtering. These
open frame modules are available either in surface-mount (-S) or in through-hole form.
* UL is a registered trademark of Underwriters Laboratories, Inc.
â CSA is a registered trademark of Canadian Standards Association.
â¡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
Document No: DS03-122 ver. 1.44