HASS-200-S Datasheet, PDF (2/3 Pages) LEM – Current Transducer HASS 50 .. 600-S
Current Transducer HASS 50 .. 600-S
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
Standard
-40 .. +105
°C
-40 .. +105
°C
55 g
EN 50178: 1997
Notes: 1) It is possible to overdrive Vref with an external reference voltage between
0.5 - 2.65 V providing its ability to sink or source approximately 5 mA
2) Maximum supply voltage (not operating) <6.5 V
3) Excluding offset and magnetic offset voltage
4) Small signal only to avoid excessive heatings of the magnetic core.
Insulation coordination
Ud
Rms voltage for AC insulation test, 50 Hz, 1 min
3.3
kV
Ue
Partial discharge extinction rms voltage @ 10 pC
>1
kV
ÛW
Impulse withstand voltage 1.2/50 µs
6
kV
Min
dCp
Creepage distance
dCI
Clearance distance
CTI Comparative Tracking Index (group I)
>5.5 mm
>5.5 mm
>600
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
●● Over voltage category OV 3
●● Pollution degree PD2
●● Non-uniform field
dCp, dCI, ÛW
Basic insulation
Reinforced insulation
EN 50178
Rated insulation voltage
600 V
300 V
IEC 61010-1
Nominal voltage
600 V
150 V
Safety
This transducer must be used in limited-energy secondary circuits according to
IEC 61010-1.
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer’s
operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury
and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
5November2014/Version 17