HASS-200-S Datasheet, PDF (1/3 Pages) LEM – Current Transducer HASS 50 .. 600-S | |||
|
Current Transducer HASS 50 .. 600-S
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic separation between the primary circuit and the secondary
circuit.
IPN = 50 .. 600 A
Electrical data
All data are given with RL = 10 kâ¦
Primary nominal Primary current
rms current measuring range
IPN (A)
50
IPM (A)
±150
100
±300
200
±600
300
±900
400
±1100
500
±1100
600
±1100
GTh
Theoretical sensitivity @ IPN
Vout
Analog output voltage @ IP
Vref
Reference voltage 1) Output voltage
Output impedance
Load impedance
RL
Load resistance
Rout
Output internal resistance
CL
Capacitive loading (±20 %)
UC
Supply voltage (±5 %) 2)
IC
Current consumption @ UC = 5 V
Type
HASS 50-S
HASS 100-S
HASS 200-S
HASS 300-S
HASS 400-S
HASS 500-S
HASS 600-S
0.625 V/ IPN
VOE ±(0.625·IP/ IPN) V
2.5 ±0.025
V
typ. 200
â¦
â¥200
â¦
â¥2
kâ¦
<5
â¦
= 4.7
nF
5
V
19 (typ) mA
25 (max) mA
Accuracy - Dynamic performance data
X
εL
TCVOE
TCVref
TCG
Accuracy 3) @ IPN, TA = 25° C
Linearity error
0 .. IPN
0 .. IPM
Temperature coefficient of VOE
Temperature coefficient of Vref
Temperature coefficient of G
â¤Â±1
â¤Â±0.5
â¤Â±1
(Vout - Vref @ IP = 0) â¤Â±0.1
â¤Â±190
â¤Â±250
%
%
%
mV/K
ppm/K
ppm/K
VOE
Electrical offset voltage @ IP = 0, TA = 25 °C
VOM
Magnetic offset voltage @ IP = 0
after an overload of IPM
tra
Reaction time to 10 % of IPN step
tr
Step response time to 90 % of IPN HASS 50-S
others
Vref ±0.015
V
<±0.4
%
<3
µs
<4 µs
<3.5 µs
di/dt di/dt accurately followed IPN â¥100 A
IPN <100 A
Vno
Output voltage noise (DC .. 20 MHz)
BW
Frequency bandwidth (-3 dB) 4)
100
A/µs
IPN A/µs
<40 mVpp
DC .. 240
kHz
Features
ââ Hall effect measuring principle
ââ Galvanic separation between
primary and secondary circuit
ââ Insulation test voltage 3300 V
ââ Low power consumption
ââ Single power supply +5 V
ââ Fixed offset & sensitivity
ââ Insulating plastic case recognized
according to UL 94-V0.
Advantages
ââ Easy installation
ââ Small size and space saving
ââ Only one design for wide current
ratings range
ââ High immunity to external
interference
ââ Internal & external reference.
Applications
ââ AC variable speed drives and
servo motor drives
ââ Static converters for DC motor
drives
ââ Battery supplied applications
ââ Uninterruptible Power Supplies
(UPS)
ââ Switched Mode Power Supplies
(SMPS)
ââ Power supplies for welding
applications.
Application domain
ââ Industrial.
74.71.25.000.0, 74.71.34.000.0, 74.71.44.000.0, 74.71.46.000.0, 74.71.48.000.0, 74.71.50.000.0, 74.71.52.000.0
5November2014/Version 17
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
|
▷ |