08 | Keysight | E6702F cdma2000/IS-95/AMPS Lab Application - Technical Overview
Multi-unit synchronization
Functionality
Sync to external test set
External test set LAN address
Synchronization fanout
Synchronization results
Synchronization accuracy
Hybrid mode
Functionality
Basic hybrid mode test capabilities
Advanced hybrid mode test capabilities
(requires the use of the Software Concepts
MOB-IP-SIM)
Allows any test set to be time-synchronized to another running
either the E6706G or E6702G; synchronization requires one unit be
designated as the time server and one as the client; the timebase
and trigger outputs of the server must be connected to the client’s
timebase and trigger inputs; the test sets must also be on a LAN
using the same address segment
One button command to perform the synchronization
User entry of the time server’s LAN address (IPv4 address)
Maximum of four client test sets can be driven from a single timing
server; unlimited number can be synchronized when they are daisy-
chained together (one unit to another)
Server operation complete and client operation complete
Typically < 1 µs
Supports cdma2000/1xEV-DO hybrid mode operation when used
with an E5515C/E running the E6706G 1xEV-DO lab application;
requires that the two units are synchronized using the built-in multi-
unit synchronization capability
–– Hybrid mode system acquisition
–– 1xEV-DO power save mode
–– Preferred control channel cycle negotiation
–– Dual-idle operation on CDMA and 1xEV-DO
–– CDMA voice call origination in dual-idle state
–– CDMA voice call origination in dormant 1xEV-DO state
–– CDMA voice call origination in 1xEV-DO connected state
–– CDMA voice call termination in dual-idle state
–– CDMA voice call termination in CDMA idle/1xEV-DO dormant
state
–– CDMA voice call termination in 1xEV-DO connected state
–– SMS origination in dual-idle state
–– SMS origination in CDMA idle/1xEV-DO dormant state
–– SMS origination in 1xEV-DO connected state
–– SMS termination in dual-idle state
–– SMS termination in CDMA idle/1xEV-DO dormant state
–– SMS termination in 1xEV-DO connected state
–– 1xEV-DO packet data call origination in dual-idle state
–– 1xEV-DO packet data call re-origination in 1xEV-DO dormant
state
–– 1xEV-DO packet data call termination in 1xEV-DO dormant
state
–– CDMA packet data call when 1xEV-DO service is unavailable
–– MIP call when using static home IP
–– MIP call when using dynamic home IP
–– MIP to SIP fallback if MIP call fails while trying packet data
call on 1xEV-DO
–– MIP to SIP fallback if MIP call fails while trying packet data
call on CDMA
–– Active 1xEV-DO to CDMA data session handoffs
–– Dormant 1xEV-DO to CDMA data session handoff
–– Dormant CDMA to 1xEV-DO data session handoff
–– 1xEV-DO to CDMA to 1xEV-DO data session hand-back