U2702A Datasheet, PDF (6/12 Pages) Keysight Technologies – USB Modular Oscilloscope
6 | Keysight | U2701A/U2702A USB Modular Oscilloscope - Data Sheet
Performance specifications1
Vertical system: oscilloscope channels
Bandwidth (–3 dB)
Scope channel triggering
Trigger sensitivity
U2701A: DC to 100 MHz
U2702A: DC to 200 MHz
< 10 mV/div: greater of 1 div or 5mV; ≥ 10 mV/div: 0.6 div
Performance characteristics2
Acquisition: oscilloscope channels
Real time sample rate
–– 2 channels interleaved
–– Each channel
Standard memory depth
–– 2 channels interleaved
–– Each channel
Vertical resolution
Peak detection
Averaging
Filter
Sweep modes
Vertical system: oscilloscope channels
Scope channels
AC coupled
Calculated rise time (= 0.35/bandwidth)
Single-shot bandwidth
Range
Maximum input 3
Offset range
Dynamic range
Input impedance
Coupling
BW limit
Standard probes
ESD tolerance
Noise peak-to-peak
DC vertical offset accuracy
DC vertical gain accuracy
1 GSa/s
500 MSa/s
Normal
32 Mpts
16 Mpts
Single-shot
64 Mpts
32 Mpts
8 bits
Yes
Any number from 1 to 999
Sin(x)/x interpolation for time base 1 ns to 100 ns
Auto, normal, single
U2701A/U2702A: Ch 1 and Ch 2 simultaneous acquisition
U2701A: 3.5 Hz to 100 MHz
U2702A: 3.5 Hz to 200 MHz
U2701A: 3.5 ns
U2702A: 1.75 ns
U2701A: 100 MHz
U2702A: 200 MHz
2 mV/div to 5 V/div (1 MΩ)
CAT I 30 Vrms, 42 Vpk
±4 div
Example: ±8 mV on 2 mV/div; ±20 V on 5 V/div
±4 div
1 MΩ: ≈ 16 pF
AC, DC, Ground
≈ 25 MHz
10:1 Passive probe 150 MHz 1.2 m
10:1 Passive probe 300 MHz 1.2 m
±2 kV
3 mVpp
≤ 200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value;
> 200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value
±4.0% of full scale
1.  All specifications are warranted. specifications are valid after a 30-minute warm-up and within ±100 ºC of last calibration temperature.
2.  All characteristics are typical performance values and are not warranted. Characteristics are valid after a 30-minute warm-up period and within ±10 ºC of
last calibration temperature.
3.  Under standalone use, you are only allowed to measure up to CAT I 30 Vrms. For high-voltage measurement up to CAT I 300 Vrms, you must install the L-
Mount kit on the U2701A/U2702A before plugging it into the product chassis. Ensure that the L-Mount kit installed on your modular oscilloscope is screwed
to the product chassis to ensure proper chassis grounding. Note that you are required to use the provided 10:1 probes (N2862A/N2863A) for high-voltage
measurements to avoid damaging your instrument.