English
Language : 

E1962B Datasheet, PDF (6/27 Pages) Agilent(Hewlett-Packard) – cdma2000/IS-95/AMPS Mobile Test Application
06 | Keysight | E1962B cdma2000/IS-95/AMPS Mobile Test Application - Technical Overview
Analog specifications
AMPS active cell call processing functionality
–– Call control (“one button commands”): Register, BS call originate, BS call discon-
nect, MS call originate (auto answer), and MS call disconnect
–– Call setup parameters: Control channel, voice channel, SID, SAT, and power level
–– Handoff support: Hard handoff to new channel
–– Registration reported mobile information: ESN in decimal, ESN in hex, MIN1, MIN2,
phone number, station class mark (SCM), and called number
AMPS test mode functionality
Usage: The mobile station must be setup on a channel without the test set (using internal
test mode commands in the mobile); the test set provides RF generator output, and RF
and audio analysis input; this mode provides no signaling
Spectrum monitor
–– Input frequency ranges:
–– 411 to 420 MHz
–– 450 to 484 MHz
–– 824 to 934 MHz
–– 1700 to 1980 MHz
–– Reference level: Auto or manual
–– Manual reference level range: +37 to –50 dBm
–– Display dB per division: 20.0 to 0.1 dB per division
–– Level measurement accuracy: Typically < ± 1.0 dB, 15 to 55 °C (calibrated against
average power and within ± 10 degrees of calibration temperature; calibration must
occur between 20 to 55 °C)
Display frequency span and resolution bandwidth (coupled):
0 Hz span
125 kHz span
300 Hz RBW
500 kHz span
1 kHz RBW
1.25 MHz span
1 kHz RBW
2.5 MHz span
10 kHz RBW
4 MHz span
30 kHz RBW
5 MHz span
30 kHz RBW
10 MHz span
100 kHz RBW
12 MHz span
100 kHz RBW
20 MHz span
100 kHz RBW
40 MHz span
300 kHz RBW
80 MHz span
1 MHz RBW
100 MHz span
5 MHz RBW
–– Trigger: Immediate, RF rise, protocol, or external
–– Trigger arm: Single or continuous
–– Trigger delay: –50 to 50 ms
–– Zero span trace time: 60 μs to 70 ms
–– Zero span resolution bandwidth: 100 kHz, 300 kHz, or 1 MHz
–– Detector: Peak detection or sample detection
–– Trace mode: Clear write, max hold, or min hold
–– Markers: Three user markers
–– Marker modes: Off, position, or delta
–– Marker functions: Peak search, marker to expected frequency, and marker to expect-
ed power