05 | Keysight | DTMB (CTTB) X-Series Measurement Application N6156A & W6156A - Technical Overview
RF Transmitter Tests
The RF transmitter test requirements
for DTMB transmitter and exciter are
defined in GY/T 229.4 2008 and GY/T
229.2 2008 standards. Table 1 shows
RF transmitter and exciter tests
defined by the specification along
with the corresponding measure-
ments provided by the DTMB (CTTB)
measurement application.
Table 1. Required RF transmitter and exciter measurements and the corresponding measurements in
N/W6156A and other modes
Test item
GY/T 229.4 GY/T 229.2 2008
2008
(For exciter
(For transmitter measurement)
measurement)
N/W6156A DTMB(CTTB)
measurement application
Frequency
adjustable step
●
Spectrum analyzer mode
●
(marker counter function)
Frequency
stability
Spectrum analyzer mode
●
●
(marker counter function)
Frequency
accuracy
Spectrum analyzer mode
●
●
(marker counter)
RF power
Channel power
●
(RF spectrum view)
RF power stability
●
Channel power
●
(RF spectrum view)
RF effective
bandwidth
Spectrum analyzer mode
●
(marker counter function)
Roll factor
Spectrum analyzer mode
●
(marker counter function)
Shoulder
Channel power (shoulder
attenuation
●
●
attenuation view)
Spectrum mask
●
Channel power (spectrum
mask view) or spectrum
emission mask
In-band spectrum
flatness
●
Modulation accuracy
●
(spectral flatness view)
Useless power in
adjacent channel
●
ACP
●
Power outside
adjacent channel
●
ACP
●
Phase noise
N/W9068A phase noise
●
●
measurement application
Peak-to-average
power ratio
Power stat CCDF
●
Modulation
error ratio
Modulation accuracy (I/Q
●
●