5 | Keysight | U1250 Series Handheld Digital Multimeter - Data Sheet
U1251B AC voltage specifications
Function
Range
Resolution
True RMS Ac
voltage 1 2
50.000 mV
500.00 mV
1000.0 mV
5.0000 V
50.000 V
500.00 V
1000.0 V
0.001 mV
0.01 mV
0.1 mV
0.0001 V
0.001 V
0.01 V
0.1 V
Accuracy ± (% of reading + no. of least significant digit)
Frequency
30 Hz ~ 45 Hz
45 Hz ~ 1 kHz
1 kHz ~ 5 kHz
1.0+60
0.6+40
1.0+40
0.6+25
1.0+25
0.6+40
1.0+40
5 kHz ~ 30 kHz
1.6+60
3.5+120
N/A
N/A
U1251B AC current specifications
Function
Range
Resolution
AC current 2
500.00 µA 3
5000.0 µA
50.000 mA
440.00 mA
5.0000 A
10.000 A 4
0.01 µA
0.1 µA
0.001 mA
0.01 mA
0.0001 A
0.001 A
Accuracy ± (% of reading + no. of least significant digit)
Frequency
30 Hz ~ 45 Hz
45 Hz ~ 2 kHz
1.5+50
0.8+20
1.5+40
2 kHz ~ 20 kHz 6
3.0+80
3.0+60
2.0+40 5
3+60, <3 A/5 kHz
U1252B/U1253B AC voltage specifications
Function
Range
True RMS AC
voltage 1 7
50.000 mV
500.00 mV
1000.0 mV
5.0000 V
50.000 V
500.00 V
1000.0 V
Resolution
0.001 mV
0.01 mV
0.1 mV
0.0001 V
0.001 V
0.01 V
0.1 V
Accuracy ± (% of reading + no. of least significant digit)
Frequency
20 Hz ~ 45 Hz 45 Hz ~ 1 kHz 1 kHz ~ 5 kHz 5 kHz ~ 15 kHz 15 kHz~100 kHz 8
1.5+60
0.4+40
0.7+40
0.75+40
3.5+120
0.4+25
0.4+25
0.4+40
0.6+25
0.4+25
0.4+40
1.5+40
N/A
N/A
N/A
N/A