81160A Datasheet, PDF (32/36 Pages) Keysight Technologies – Pulse Function Arbitrary Noise Generators
32 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet
General Specifications
Power supply
Power consumption
Operating temperature
Operating altitude
Storage temp.
Stored states
Power on state
Interface
Programming language
Dimensions (WxHxD)
Bench top
Rack mount
Weight
Safety designed to
EMC tested to
Warm up time
Calibration interval
Warranty
Cooling requirements
81150A
100 V to 240 V ~, 50 to 60 Hz
100 V to 127 V ~, 50 to 400 Hz
110 W nom.
0 to 50 ºC
Up to 2000 m
–40 to 70 °C
4 named user configurations and factory default
Default or last state
2 x USB 2.0 standard A,
1 x USB 2.0 standard B,
GPIB and LAN
SCPI-1997
IEEE-488.2
LXI compliant to LXI class C (rev. 1.1)
81160A
100 V to 240 V ~, 50 to 60 Hz
100 V to 127 V ~, 50 to 400 Hz
90 W nom.
0 to 55 ºC
Up to 2000 m
–40 to 70 °C
4 named user configurations and factory default
Default or last state
2 x USB 2.0 standard A,
1 x USB 2.0 standard B,
GPIB and LAN
SCPI-1997
IEEE-488.2
LXI compliant to LXI class C (rev. 1.1)
439 mm x 108 mm x 456 mm
428 mm x 89 mm x 439 mm
8 kg
IEC61010-1
UL61010
CSA22.2 61010.1 certified
IEC61326
30 min.
2 years recommended
3-year standard
When operating the instrument choose a location that
provides at least 80 mm of clearance at rear, and at
least 30mm of clearance at each side
439 mm x 108 mm x 456 mm
428 mm x 89 mm x 439 mm
8 kg
IEC61010-1
UL61010
CSA22.2 61010.1 certified
IEC61326
30 min.
2 years recommended
3-year standard
When operating the instrument choose a location that
provides at least 80 mm of clearance at rear, and at
least 30mm of clearance at each side
Definitions
Specification (spec.)
Typical (typ.)
Nominal (nom.)
Measured (meas.)
Accuracy
The warranted performance of a calibrated instrument that has been stored for a minimum of 2 hours within the
operating temperature range of 0 °C to 55 °C and after a 45-minute warm up period. Within ± 10 °C after autocal.
All specifications include measurement uncertainty and were created in compliance with ISO-17025 and Z540
methods. Data published in this document are specifications (spec.) only where specifically indicated.
The characteristic performance, which 80% or more of manufactured instruments will meet. This data is not
warranted, does not include measurement uncertainty, and is valid only at room temperature (approximately 23 °C).
The mean or average characteristic performance, or the value of an attribute that is determined by design such
as a connector type, physical dimension, or operating speed. This data is not warranted and is measured at room
temperature (approximately 23 °C).
An attribute measured during development for purposes of communicating the expected performance. This data is
not warranted and is measured at room temperature (approximately 23 °C).
Represents the traceable accuracy of a specified parameter. Includes measurement error and timebase error, and
calibration source uncertainty.