English
Language : 

Z-SERIES Datasheet, PDF (25/41 Pages) Keysight Technologies – Infiniium Z-Series Oscilloscopes
25 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet
Compliance and Automation Testing: Switch Matrix Support
Comprehensive testing, easily achieved
Eliminate reconnections (reducing errors)
Compliance applications on the Z-Series support a switch
matrix, making testing simple by automating tests for each lane
of a multi-lane bus. Typical testing requires reconnecting the
oscilloscope each time you switch a lane, which causes wasted
time and inaccuracies. The Z-Series solves this problem by
supporting switch matrix through its compliance test. Simply
connect the switch to the oscilloscope and all the lanes, and then
click Run to complete full testing of your entire device.
Maintain accuracy
The framework fully supports Keysight’s PrecisionProbe software
(N2809A) and InfiniiSim software (N5465A). This gives you the
ability to characterize every switch path to the device under test
(both magnitude and skew) and ensure that all of them maintain
the same level of accuracy.
Customize your testing
Use the remote programming interface (standard feature on the
Z-Series) and N5467A user-defined application for device control,
instrument control and test customization.
Software description
DisplayPort switch
matrix
HDMI switch matrix
MIPI D-PHY switch
matrix
MIPI M-PHY switch
matrix
PCIe® switch matrix
Ethernet KR switch
matrix
QSFP+ switch matrix
UDA switch matrix
100GBASE-CR10
switch matrix
100GBASE-KR4 switch
matrix
100GBASE-CR4 switch
matrix
10GBASE-T switch
matrix
Model number
Fixed 1
Floating 2
Node locked Transportable
U7232C-7FP U7232C-7TP
Server based
N5435A-701
N5399C-7FP N5399C-7TP N5435A-702
U7238C-7FP U7238C-7TP N5435A-703
U7249C-7FP U7249C-7TP N5435A-704
N5393D-7FP N5393D-7TP N5435A-705
N8814B-7FP N8814B-7TP N5435A-706
N6468A-7FP
N5467B-7FP
N8828A-7FP
N6468A-7TP
N5467B-7TP
N8828A-7TP
N5435A-707
N5435A-708
N5435A-709
N8829A-7FP N5435A-710 N8829A-7TP
N8830A-7FP N8830A-7TP N5430A-711
N5392A-7FP N5392A-7TP N5430A-712
Clock
L1
DUT
L2
L3
SMA
probe
head
SMA
probe
head
SMA
probe
head
SMA
probe
head
Ch1
Ch2
Scope
Ch3
Ch4
Switch matrix
+3.3V
Typical switch configuration for HDMI testing (now supported in the
Z-Series).
Skews between switch paths are easily maintained with Keysight’s
unique software.
1.  Factory-installed on new scope purchase or user-installed on existing
scope.
2.  Must be user-installed.