English
Language : 

N1076A Datasheet, PDF (17/19 Pages) Keysight Technologies – Electrical and Optical Clock Data Recovery Solutions
17 | Keysight | Electrical and Optical Clock Data Recovery Solutions - Data Sheet
Accessories
Part number when
ordered with a
new N1076/N1077
purchase
N1076A/N1077A-1CM
N1076A/N1077A-1CN
N1076A/N1077A-EQ6
N1076A/N1077A-EQ9
N1076A-2P2
N1076A-2P3
N1076A-DC1
N1076A-CR1
N1077A-CR1
Part number
when ordered
AFTER original
purchase
N1027A-RM1
N1027A-RM2
N1027A-EQ6
N1027A-EQ9
N1027A-2P2
N1027A-2P3
N1027A-DC1
N1027A-76A
N1027A-77A
Description
Single instrument rack mount kit
Dual instrument side-by-side rack mount kit
Equalizer, 2.92 mm (m) to 2.92 mm (f), 6 dB
Equalizer, 2.92 mm (m) to 2.92 mm (f), 9 dB
Microwave pick-off tee 2.4 mm connectors, matched pair
Microwave pick-off tee 2.92 mm connectors, matched pair
Assembly, delay cable, 18.2 ns
Clock recovery phase matching kit for N1076A electrical
Electrical kit contents
Qty 2 cable assy, coaxial 2.92 mm (m) to 2.92 mm (m)
18 in ch length
Qty 2 cable assy, coaxial 2.92 mm (m) to 2.92 mm (m)
1 m length
Qty 1 18.2 ns electrical delay line
Qty 1 microwave pick-off tee 2.92 mm connectors,
matched pair
Qty 2 equalizer, 2.92 mm (m) to 2.92 mm (f), 6 dB
Qty 2 equalizer, 2.92 mm (m) to 2.92 mm (f), 9 dB
Qty 1 T-20 Torx screwdriver
Qty 1 T-10 Torx screwdriver
Qty 1 wrench - torque 8 lb-in, 5/16 inch
Qty 1 accessory card
Clock recovery phase matching kit for N1077A optical
Optical kit contents
Qty 1 cable assy, optical 50/125 µm MM, FC/PC 1.0 m
length
Qty 1 cable assy, optical 50/125 µm MM, FC/PC 2.5 m
length
Qty 1 cable assy, optical 50/125 µm MM, FC/PC 4.5 m
length
Qty 1 cable assy, optical 9/125 µm SM, FC/PC 1.0 m
length
Qty 1 cable assy, optical 9/125 µm SM, FC/PC 3.8 m
length
Qty 1 cable assy, optical 9/125 µm SM, FC/PC 6.1 m
length
Qty 1 cable assy, coaxial 2.92 mm (m) to 2.92 mm (m)
12 in ch length
Qty 2 cable assy, coaxial 2.92 mm (m) to 2.92 mm (m)
1 m length
Qty 1 equalizer, 2.92 mm (m) to 2.92 mm (f), 6 dB
Qty 1 equalizer, 2.92 mm (m) to 2.92 mm (f), 9 dB
Qty 1 accessory card
Comment
See Note 1 below.
See Note 1 below.
See Note 2 below.
See Note 2 below.
Install on the rear-panel of an 86100D-ETR
mainframe to match clock-to-data delays.
Recommended for 86100D DCA-X applications
that have signifcant amounts of low-frequency
jitter content (e.g. SSC).
Cable(s) used between CR output and the
measurement instrument.
Cable(s) used between pick-off tee and CR input.
Install on the rear-panel of an 86100D-ETR
mainframe.
See Note 2 below.
See Note 1 below.
See Note 1 below.
Used to install the electrical delay line.
Used to install the electrical delay line.
Used to torque electrical connections.
Cabling setup instructions.
Recommended for optical applications that require
clock-to-data delay matching.
For general purpose optical measurements when
clock-to-data delay is not critical.
Multimode delay matching for N1077A with
86100D-PTB + DCA Module (86105D, 86116C).
Multimode delay matching for N1077A with
N1092x.
For general purpose single-mode optical
measurements when clock-to-data delay is not
critical.
Single-mode delay matching for N1077A with
86100D-PTB + DCA Module (86105D, 86116C).
Single-mode delay matching for N1077A with
N1092x.
Cable used between O/E output and CR input if an
external equalizer is required.
Cable(s) used between CR output and the
measurement instrument.
See Note 1 below.
See Note 1 below.
Cabling setup instructions.
Notes:
1.  External equalizers may be placed in front of the electrical clock recovery inputs to “open” a closed eye. They help the instrument recover a clock from a
signal that has been severely degraded due to excessive frequency-dependent losses.
2.  Microwave pick-off tees are used to direct a small amount of the electrical data signal to the clock recovery input. Refer to Figure 4.