Electrical Specifications for U1213A (continued)
Frequency (AC coupling)
Range
Resolution
99.99 Hz
0.01 Hz
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
99.99 kHz
0.01 kHz
999.9 kHz
0.1 kHz
–– Overload protection: 1000 V; < 20,000,000 V x Hz
Accuracy
0.2 % + 3
Minimum frequency
10 Hz
Sensitivity
Frequency sensitivity
Range
Maximum input for specified accuracy of AC
4V
40 V
400 V
1000 V
40 A
400 A
1000 A
Minimum sensitivity (R.M.S.)
45 Hz~2 kHz
0.3 V
2V
20 V
50 V
3 A (< 1 kHz)
20 A (< 1 kHz)
50 A (< 1 kHz)
10 Hz~200 kHz
0.6 V
3V
30 V (< 100 kHz)
50 V (< 10 kHz)
3 A (< 1 kHz)
20 A (< 1 kHz)
50 A (< 1 kHz)
Duty cycle
Mode
AC coupling
Range
0.1 %~99.9 %
Accuracy of full scale
0.3 % per kHz + 0.3 %
Notes:
1.  The accuracy for duty cycle is based on a 4 V square wave input to the DC 4 V range and maximum frequency up to 2 kHz. The duty cycle
range can be measured within 5 %~95 % as the signal frequency > 20 Hz.