English
Language : 

81100 Datasheet, PDF (11/13 Pages) Keysight Technologies – Pulse Pattern Generators
Common Specifications
General
User interface
Overprogramming: All parameters can
be overprogrammed (exceeding specifica-
tions) to fully exploit the hardware limits.
Setting check: Warning messages
indicate potentially conflicting parameters
due to inaccuracy. Error messages indicate
conflicting parameters.
Help key: Displays a context-sensitive
message.
Autoset key: Resolves all timing conflicts.
Non-volatile memory: Current setting is
saved on power-down. Up to nine user
settings and one fixed default setting can
be stored in the instrument.
Memory card: 99 settings can be stored
on a 1 MB PCMCIA card (MS-DOS®).
Remote control: Operates according
to IEEE standard 488.2, 1987 and SCPI
1992.0.
Function code: SH1, AH1, T6, L4, SR1,
RL1, PP0, DC1, DT1, C0.
Programming times: All checks and
display off.
ASCII command
One parameter or
mode
Typ. exec. time
30 ms typ.
Recall setting
250 ms typ.
16 k pattern transfer 600 ms typ.
Operating temperature: 0 °C to +55 °C.
Storage temperature: -40 °C to +70 °C.
Humidity: 95% r.h. up to 40 °C ambient
temperature.
EMC: conforms to EN50082-1, EN 55011,
Class A.
Noise emission: 5.7 bel typical.
Battery: Lithium CR2477-N.
Safety: IEC1010, CSA1010.
Power requirements:
100 - 240 Vac, ± 10%, 50 - 60 Hz
100 - 120 Vac, ± 10%, 400 Hz.
Power consumption: 300 VA max.
Max. dimensions: (H * W * D):
89 mm * 426 mm * 521 mm.
Weight: 9.2 kg net, 13.8 kg shipping.
Recalibration period:
Three years recommended.
Complementary products - pulse
pattern generator and oscilloscopes
(real time or sampling)
• DSO 80804B/80604B
• DSO 80404B
• DSO 80304B
• D/MSO 6100/8104A
• D/MSO 6050/8064A
• D/MSO6030
• D/MSO 601x
• DSO 3000
Inputs and outputs
Clock input/PLL reference and external
input.
Connectors: SMA (f) 3.5 mm.
Input impedance: 50 Ω.
Termination voltage: -2.10 V to 3.30 V.
Input sensitivity: < 400 mV typ.
Max. input voltage: -3 V to + 6 V.
Input transitions: < 20 ns.
Only valid for clock input/PLL reference.
One input is used for clock input or for
the PLL reference alternatively.
Reference: The internal PLL is locked to
the 1, 2, 5 or 10 MHz.
External clock: The output period is
determined by the signal at clock input.
Clock input frequency: 170 kHz to
660 MHz (at 50% ±10% duty cycle).
Delay from input trigger output: 21 ns.
Delay from input to output: 53 ns.
Threshold: ac coupled. Only valid for
external input.
External input: Used for external started
or gated.
Input frequency: DC to 330 MHz.
Delay from external input to trigger
output: 22 ns + 0 to 1 period.
Delay from external input to output:
54 ns + 0 to 1 period.
Specifications
Specifications describe the instrument’s warranted performance. Non-warranted values are described as typical. All specifications apply
after a 30 minute warm-up phase with 50 Ω source/load resistance. All specifications are valid from 0 °C to 55 °C ambient temperature.
Data Sheet 81100 Family of Pulse Pattern Generators
11