Measurement Conditions
Capacitance (Charge System)
Capacitance is calculated from expression (9) by measuring the charge time constant (τ) of the capacitor (C). Prior to measurement, the
capacitor is discharged by shorting both pins of the device for at least 30 minutes. In addition, use the polarity indicator on the device to
determine correct orientation of capacitor for charging.
Capacitance: C =
τ
Rc
(F) (9)
Switch
Rc
Eo
+
C–
Vc
Eo: 3.0 (V) Product with maximum operating voltage of 3.5 V
5.0 (V) Product with maximum operating voltage of 5.5 V
6.0 (V) Product with maximum operating voltage of 6.5 V
10.0 (V) Product with maximum operating voltage of 11 V
12.0 (V) Product with maximum operating voltage of 12 V
τ:
Time from start of charging until Vc becomes 0.632 Eo (V) (seconds)
Rc: See table below (Ω).
Charge Resistor Selection Guide
Cap
FA
FE
FS
FY
FYD FYH FYL
FR
FM, FME
FMR, FML
FMC
FG
FGR
FGH
FT
0.010 F –
–
–
–
– 5000 Ω –
5000 Ω
– 5000 Ω –
–
0.022 F 1000 Ω – 1000 Ω 2000 Ω 2000 Ω 2000 Ω 2000 Ω 2000 Ω
– 2000 Ω –
–
0.033 F –
–
–
–
–
–
–
Discharge
–
–
–
–
0.047 F 1000 Ω 1000 Ω 1000 Ω 2000 Ω 1000 Ω 2000 Ω 1000 Ω 2000 Ω 1000 Ω 2000 Ω –
–
0.10 F 510 Ω 510 Ω 510 Ω 1000 Ω 510 Ω – 1000 Ω 1000 Ω 1000 Ω 1000 Ω Discharge 510 Ω
0.22 F 200 Ω 200 Ω 200 Ω 510 Ω 510 Ω
–
510 Ω
0H: Discharge
0V: 1000 Ω
–
1000 Ω Discharge 200 Ω
0.33 F
–
–
–
–
–
–
–
–
Discharge –
–
–
0.47 F 100 Ω 100 Ω 100 Ω 200 Ω 200 Ω – 200 Ω
–
– 1000 Ω Discharge 100 Ω
1.0 F 51 Ω 51 Ω 100 Ω 100 Ω 100 Ω – 100 Ω
–
–
510 Ω Discharge 100 Ω
1.4 F
–
–
– 200 Ω –
–
–
–
–
–
–
–
1.5 F
– 51 Ω –
–
–
–
–
–
–
510 Ω
–
–
2.2 F
–
–
– 100 Ω –
–
–
–
– 200 Ω –
51 Ω
2.7 F
–
–
–
–
–
–
–
–
–
–
–
–
3.3 F
–
–
–
–
–
–
–
–
–
–
–
51 Ω
4.7 F
–
–
–
–
–
–
–
–
–
100 Ω
–
–
5.0 F
–
– 100 Ω –
–
–
–
–
–
–
–
–
5.6 F
–
–
–
–
–
–
–
–
–
–
–
20 Ω
10.0 F
–
–
–
–
–
–
–
–
–
–
–
–
22.0 F
–
–
–
–
–
–
–
–
–
–
–
–
50.0 F
–
–
–
–
–
–
–
–
–
–
–
–
100.0 F –
–
–
–
–
–
–
–
–
–
–
–
200.0 F –
–
–
–
–
–
–
–
–
–
–
–
FC, FCS
–
Discharge
–
–
Discharge
Discharge
–
Discharge
Discharge
–
–
–
–
–
–
–
–
–
–
–
–
–
HV
–
–
–
–
–
–
–
–
Discharge
–
–
–
Discharge
–
Discharge
–
–
Discharge
Discharge
Discharge
Discharge
Discharge
*Capacitance values according to the constant current discharge method.
*HV Series capacitance is measured by discharge system
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
S6016_FR • 3/7/2014 8