English
Language : 

FR0H104ZF Datasheet, PDF (12/14 Pages) Kemet Corporation – Supercapacitors FR Series
Supercapacitors – FR Series
Notes on Using Supercapacitors or Electric Double-Layer Capacitors (EDLCs) cont’d
2. Mounting
2.1 Mounting onto a reflow furnace
Except for the FC series, it is not possible to mount this capacitor onto an IR / VPS reflow furnace. Do not immerse the capacitor
into a soldering dip tank.
2.2 Flow soldering conditions
See Recommended Reflow Curves in Section – Precautions for Use
2.3 Installation using a soldering iron
Care must be taken to prevent the soldering iron from touching other parts when soldering. Keep the tip of the soldering iron under
400ºC and soldering time to within 3 seconds. Always make sure that the temperature of the tip is controlled. Internal capacitor
resistance is likely to increase if the terminals are overheated.
2.4 Lead terminal processing
Do not attempt to bend or polish the capacitor terminals with sand paper, etc. Soldering may not be possible if the metallic plating
is removed from the top of the terminals.
2.5 Cleaning, Coating, and Potting
Except for the FM series, cleaning, coating and potting must not be carried out. Consult KEMET if this type of procedure is
necessary. Terminals should be dried at less than the maximum operating temperature after cleaning.
3. Storage
3.1 Temperature and humidity
Make sure that the supercapacitor is stored according to the following conditions: Temperature: 5 – 35ºC (Standard 25ºC),
Humidity: 20 – 70% (Standard: 50%). Do not allow the build up of condensation through sudden temperature change.
3.2 Environment conditions
Make sure there are no corrosive gasses such as sulfur dioxide, as penetration of the lead terminals is possible. Always store this
item in an area with low dust and dirt levels. Make sure that the packaging will not be deformed through heavy loading, movement
and/or knocks. Keep out of direct sunlight and away from radiation, static electricity and magnetic fields.
3.3 Maximum storage period
This item may be stored up to one year from the date of delivery if stored at the conditions stated above.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
S6016_FR • 3/7/2014 12