Performance Characteristics
Supercapacitors should not be used for applications such as ripple absorption because of their high internal resistance (several
hundred mΩ to a hundred Ω) compared to aluminum electrolytic capacitors. Thus, its main use would be similar to that of secondary
battery such as power back-up in DC circuit. The following list shows the characteristics of supercapacitors as compared to aluminum
electrolytic capacitors for power back-up and secondary batteries.
Secondary Battery
NiCd
Lithium Ion
Capacitor
Aluminum Electrolytic
Supercapacitor
Back-up ability
–
–
–
–
Eco-hazard
Cd
–
–
–
Operating Temperature Range
-20 to +60ºC
-20 to +50ºC
-55 to +105ºC
-40 to +85ºC (FR, FT)
Charge Time
Charge/Discharge Life Time
Restrictions on Charge/Discharge
few hours
approximately 500 times
yes
few hours
approximately 500 to 1,000
times
yes
few seconds
limitless (*1)
none
few seconds
limitless (*1)
none
Flow Soldering
not applicable
not applicable
applicable
applicable
Automatic Mounting
not applicable
not applicable
applicable
applicable
(FM and FC series)
Safety Risks
leakage, explosion
leakage, combustion,
explosion, ignition
heat-up, explosion
gas emission (*2)
(*1) Aluminum electrolytic capacitors and supercapacitors have limited lifetime. However, when used under proper conditions, both can operate within a
predetermined lifetime.
(*2) There is no harm as it is a mere leak of water vapor which transitioned from water contained in the electrolyte (diluted sulfuric acid). However, application of
abnormal voltage surge exceeding maximum operating voltage may result in leakage and explosion.
Typical Applications
Intended Use (Guideline) Power Supply (Guideline)
Long time back-up
500 μA and below
Application
Embedded memory
backup
Motor driver
Examples of Equipment
DVD player, television,
game console, set-top box
DVD player, printer,
projector, camera
Series
FR series
Environmental Compliance
All KEMET supercapacitors are RoHS Compliant.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
S6016_FR • 3/7/2014 3