English
Language : 

C961U222MWWDAA7317 Datasheet, PDF (8/15 Pages) Kemet Corporation – Safety Standard Recognized, 900 Series, Encapsulated, AS Type, X1 760 VAC/Y1 500 VAC (Industrial Grade)
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AS Type, X1 760 VAC/Y1 500 VAC (Industrial Grade)
Table 2 – Performance & Reliability: Test Methods and Conditions cont'd
Item
Flame Test
Specification
The capacitor flame extinguishes as
follows:
Cycle
1~4
5
Time
30 seconds
maximum
60 seconds
maximum
Test Method
The capacitor is exposed to a flame for 15 seconds and then
removed for 15 seconds. This test is repeated for 5 cycles.
Capacitor
Flame
76
38 127
Gas Burner
20º
(Unit:mm)
The capacitors are individually wrapped in at least one, but not
more than two, complete layers of cheesecloth. They are then
subjected to 20 discharges. The interval between successive
discharges is 5 seconds. The VAC is maintained for 2 minutes
after the last discharge.
S1
F L1 L2
R
C1 C2 C3 CX
Ct
Vt
Tr S2 Vac L3
L4
Active Flammability
The cheesecloth should not ignite.
Oscilloscope
C1, 2
1 μF ±10%
L1-4 1.5 Mh ±20% 16A Rod core choke
R
100±2%
Ct
3 μF ±5% 10 kV
F
Fuse, Rated 10A
C3
0.033 μF ±5% 10 kV
Cx
Test capacitor
VAC
VR ±5%
VR
Rated Voltage
Vt Voltage applied to Ct
Vx
5kV
time
1 “Room Condition” is defined as follows: Temperature: 15 ~ 35°C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com C1066_X1_760 VAC_Y1_500 VAC • 1/13/2017 8