English
Language : 

UGE0421AY4 Datasheet, PDF (9/16 Pages) IXYS Corporation – High Voltage rectifiers Hochspannungs-gleichrichter
UGE 1112 AY4
10
A
IF 8
6
T(vj) = 150°C
T(vj) = 25°C
4
ab
2
0
3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5V
VF
Fig. 1: Forward characteristics
Instantaneous forward current IF as a function of instantaneous forward
voltage drop VF for junction temperature T(vj) = 25°C and T(vj) = 150°C
a = Mean value characteristic
b = Limit value characteristic
A
120
IFSM
100
80
60
a
40
b
20
0
10-3
10-2
10-1
100 s 101
t
Fig. 2: Characteristics of maximum permissible current
The curves show the non repetitive peak one cycle surge forward
current IFSM as a function of time t and serve for rating protective
devices.
a = Initial state
b = Initial state
T(vj) = 45°C
T(vj) = 150°C
104
W
PRSM
103
102
5
A
IF(AV) 4
3
2
1
5+6
IFAV
180°
4
3
2
1
101
10-6
10-5
10-4
10-3 s 10-2
t
Fig. 3: Power loss
Non repetitive peak reverse power loss PRSM as a function of time t,
T(vj) = 150°C
IXYS reserve the right to change limits, test conditions and dimensions.
0
0
30 60 90 120 150°C
TA
Fig. 4: Load diagramm
Mean forward current IF(AV) of one module for a sine half wave for various
cooling modes as a function of the cooling medium temperature Tamb for a
resistive load (horizontal mounting).
Cooling modes
1 = air self cooling
2 = air self cooling
3 = forced air cooling
4 = forced air cooling
5 = oil cooling
6 = oil cooling
without cooling plate
with cooling plate
without cooling plate
with cooling plate
without cooling plate
with cooling plate
9