English
Language : 

CPC7594 Datasheet, PDF (9/20 Pages) Clare, Inc. – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
CPC7594
1.7 Digital I/O Electrical Specifications
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
Input Characteristics
Input voltage, Logic low
Input voltage, Logic high
Input voltage falling
Input voltage rising
VIL
0.8
1.0
-
V
VIH
1.7
2.0
Input leakage current,
INRINGING and INTEST, VDD = 5.5 V, VBAT = -75 V, VHI = 2.4 V
IIH
-
0.1
1
A
Logic high
Input leakage current,
INRINGING and INTEST, VDD = 5.5 V, VBAT = -75 V, VIL = 0.4 V
IIL
-
0.1
1
A
Logic low
Input leakage current,
LATCH Logic high
VDD = 4.5 V, VBAT = -75 V, VIH = 2.4 V
IIH
7
19
-
A
LATCH Pull-up
Minimum Load
VDD = 4.5 V, VBAT = -75 V, IIN = -10 A Logic = High
True
Latch input transitions to logic high.
Input leakage current,
LATCH Logic low
VDD = 5.5 V, VBAT = -75 V, VIL = 0.4 V
IIL
-
46
125
A
Input leakage current,
TSD Logic high
VDD = 5.5 V, VBAT = -75 V, VIH = 2.4 V
IIH
10
16
30
A
Input leakage current,
TSD Logic low
VDD = 5.5 V, VBAT = -75 V, VIL = 0.4 V
IIL
10
16
30
A
Output Characteristics
Output voltage,
TSD Logic high
VDD = 5.5 V, VBAT = -75 V, ITSD = A VTSD_off
2.4
VDD
-
V
Output voltage,
TSD Logic low
VDD = 5.5 V, VBAT = -75 V, ITSD = mA VTSD_on
-
0
0.4
V
1.8 Voltage and Power Specifications
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
Voltage Requirements
VDD
-
VDD
4.5
5.0
5.5
V
VBAT1
-
VBAT
-19
-48
-72
V
1VBAT is used only for internal protection circuitry. If VBAT rises above-10 V, the device will enter the all-off state and will remain in the all-off state until the battery
drops below approximately -15 V
Power Specifications
Power consumption
VDD = 5 V, VBAT = -48 V,
Measure IDD and IBAT,
Talk and All-Off States
P
-
5.5
10
mW
All other states
P
-
6.5
10
mW
VDD = 5 V, VBAT = -48 V
VDD current
Talk and All-Off states
IDD
1.1
2.0
mA
Ringing and Test states
IDD
-
1.3
2.0
mA
VBAT current
VDD = 5 V, VBAT = -72 V, All states
IBAT
-
0.1
10
A
R04