English
Language : 

CPC5002 Datasheet, PDF (4/14 Pages) IXYS Corporation – Dual High-Speed Open-Drain
INTEGRATED CIRCUITS DIVISION
CPC5002
1.5 Recommended Operating Conditions
Parameter
Supply Voltage
LED Forward Current
Output Drive
Operating Ambient Temperature
Symbol Min Typ Max Units
VDD
2.7
-
5.5
V
IF
1.4
1.5
10
mA
ISINK
6
mA
TA
-40
+85 °C
1.6 General Conditions
Specifications cover the operating temperature range TA = -40°C to +85°C and supply range VDD = 2.7V to 5.5V.
Unless otherwise specified, minimum and maximum values are guaranteed by production testing. Typical values are
the result of engineering evaluations and are characteristic of the device at TA = 25°C and VDD = 3.3V; they are
provided for information purposes only and are not verified by manufacturing testing.
1.7 Electrical Specifications
Parameter
Input Specifications
LED Input Threshold Current
LED Forward Voltage
LED Reverse Breakdown Voltage
LED Capacitance
Output Specifications
Output Drive
High Level Leakage Current
Supply Specifications
Supply Current
1.8 Thermal Characteristics
Conditions
-
IF=1.5mA, TA=25°C
IF=10mA
IR=5A
VF=0V, f=1MHz
Symbol Min Typ Max Units
ITH
0.16 0.55
1
mA
VF
0.98 1.2 1.41
V
1.0
1.3
1.8
VR
6
-
-
V
CIN
-
50
-
pF
VDD=2.7V, ISINK=3mA
VDD=2.7V, ISINK=6mA
VDD=3.3V, ISINK=6mA
VOUT=VDD=5.5V
-
0.21 0.35
VOL
-
0.42 0.7
V
-
0.38
-
IOHL
-
0.1
10
A
VDD=3.3V, ISINK=0mA
VDD=5.5V, ISINK=0mA, TA=25°C
IDD
-
1.4
-
mA
-
2.1
3
Parameter
Conditions
Symbol
Typ
Units
Thermal Resistance, Junction to Ambient
Free Air
RJA
114
°C/W
LED Temperature Coefficient
IF=1.5mA
d----V----F-
dT
-1.3
mV/°C
Output Voltage Temperature Coefficient
ISINK=6mA
d----V----O---U----T-
dT
1.2
mV/°C
4
www.ixysic.com
R01