English
Language : 

IRF6616PBF_15 Datasheet, PDF (5/10 Pages) International Rectifier – RoHS compliant containing no lead or bormide
1000.00
100.00
10.00
TJ = 150°C
TJ = 25°C
TJ = -40°C
1.00
VGS = 0V
0.10
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1
VSD, Source-to-Drain Voltage (V)
Fig 10. Typical Source-Drain Diode Forward Voltage
120
100
80
60
40
20
0
25
50
75
100
125 150
TC , Case Temperature (°C)
Fig 12. Maximum Drain Current vs. Case Temperature
200
160
120
IRF6616PbF
1000
OPERATION IN THIS AREA
LIMITED BY R DS (on)
100
10
100µsec
1
TA = 25°C
Tj = 150°C
Single Pulse
0.1
0
1
1msec
10msec
10
100
1000
VDS , Drain-to-Source Voltage (V)
Fig11. Maximum Safe Operating Area
2.5
2.0
ID = 250µA
1.5
1.0
-75 -50 -25 0 25 50 75 100 125 150
TJ , Junction Temperature ( °C )
Fig 13. Typical Threshold Voltage vs. Junction
Temperature
ID
TOP 3.7A
4.3A
BOTTOM 15A
80
40
0
25
50
75
100
125
150
Starting T J, Junction Temperature (°C)
Fig 14. Maximum Avalanche Energy Vs. Drain Current
www.irf.com
5