X3100 Datasheet, PDF (9/40 Pages) Xicor Inc. – 3 or 4 Cell Li-Ion Battery Protection and Monitor IC | |||
|
◁ |
X3100, X3101
CONFIGURATION REGISTER
The X3100 and X3101 can be configured for specific
user requirements using the Configuration Register.
Table 1. Configuration Register Functionality
Bit(s)
0-5
6
7
8-9
10-11
12-13
14-15
Name
â
SWCEN
CELLN
VCE1-VCE0
VOC1-VOC0
VUV1-VUV0
VOV1-VOV0
Function
(donât care)
Switch Cell Charge Enable
threshold function ON/OFF
Set the number of Li-Ion battery
cells used (3 or 4)
Select Cell Charge Enable
threshold
Select over-current threshold
Select over-discharge (under
voltage) threshold
Select over-charge voltage
threshold
Table 2. Configuration RegisterâUpper Byte
15 14 13 12 11 10 9 8
VOV1 VOV0 VUV1 VUV0 VOC1 VOC0 VCE1 VCE0
X3100 Default = 33H; X3101 Default = 03H.
Table 3. Configuration RegisterâLower Byte
7
6
543210
CELLN SWCEN x x x x x x
X3100 Default = C0H; X3101 Default = 40H.
Over-charge Voltage Settings
VOV1 and VOV0 control the cell over-charge level.
See section âOver-charge Protectionâ on page 14.
Table 4. Over-charge Voltage Threshold Selection
Configuration Register
Bits
VOV1
VOV0
Operation
0
0
VOV = 4.20V (Default)
0
1
VOV = 4.25V
1
0
VOV = 4.30V
1
1
VOV = 4.35V
Over-discharge Settings
VUV1 and VUV0 control the cell over-discharge
(under voltage threshold) level. See section âOver-dis-
charge Protectionâ on page 16.
Table 5. Over-discharge Threshold Selection.
Configuration
Register Bits
VUV1 VUV0
0
0
0
1
1
0
1
1
Operation
X3100
X3101
VUV = 1.95V VUV = 2.25V
(X3101 default)
VUV = 2.05V
VUV = 2.15V
VUV = 2.25V
(X3100 default)
VUV = 2.35V
VUV = 2.45V
VUV = 2.55V
Over-current Settings
VOC1 and VOC0 control the pack over-current level.
See section âOver-Current Protectionâ on page 19.
Table 6. Over-Current Threshold Voltage Selection.
Configuration Register
Bits
VOC1
VOC0
Operation
0
0
VOC = 0.075V (Default)
0
1
VOC = 0.100V
1
0
VOC = 0.125V
1
1
VOC = 0.150V
Cell Charge Enable Settings
VCE1, VCE0 and SWCEN control the pack charge
enable function. SWCEN enables or disables a circuit
that prevents charging if the cells are at too low a volt-
age. VCE1 and VCE0 select the voltage that is recog-
nized as too low. See section âSleep Modeâ on page 16.
Table 7. Cell Charge Enable Function
Configuration
Register Bit
SWCEN
Operation
0
Charge enable function: ON
1
Charge enable function: OFF
9
FN8110.0
April 11, 2005
|
▷ |