English
Language : 

ISL6719_14 Datasheet, PDF (9/9 Pages) Intersil Corporation – 100V Linear Bias Supply
ISL6719
Dual Flat No-Lead Plastic Package (DFN)
2X
A
D
0.15 C A
2X
0.15 C B
E
5
INDEX
AREA
TOP VIEW
B
C
SIDE VIEW
SEATING
PLANE
(DATUM B)
5
1
INDEX
AREA
(DATUM A)
D2
D2/2
2
A
A3
// 0.10 C
0.08 C
67
NX k
E2
E2/2
NX L
7
N N-1
e
(Nd-1)Xe
REF.
BOTTOM VIEW
NX b
4
0.10 M C A B
NX (b)
(A1)
4
SECTION "C-C"
CL
8L
e
CC
TERMINAL TIP
FOR ODD TERMINAL/SIDE
L9.3x3
9 LEAD DUAL FLAT NO-LEAD PLASTIC PACKAGE
MILLIMETERS
SYMBOL
MIN
NOMINAL
MAX
NOTES
A
0.80
0.90
1.00
-
A1
-
-
0.05
-
A3
0.20 REF
-
b
0.20
0.25
0.30
4, 7
D
3.00 BSC
-
D2
1.85
2.00
2.10
6, 7
E
3.00 BSC
-
E2
0.80
0.95
1.05
6, 7
e
0.50 BSC
-
k
0.60
-
-
-
L
0.25
0.35
0.45
7
N
9
2
NOTES:
Rev. 0 3/06
1. Dimensioning and tolerancing conform to ASME Y14.5-1994.
2. N is the number of terminals.
3. All dimensions are in millimeters. Angles are in degrees.
4. Dimension b applies to the metallized terminal and is measured
between 0.15mm and 0.30mm from the terminal tip.
5. The configuration of the pin #1 identifier is optional, but must be
located within the zone indicated. The pin #1 identifier may be
either a mold or mark feature.
6. Dimensions D2 and E2 are for the exposed pads which provide
improved electrical and thermal performance.
7. Nominal dimensions are provided to assist with PCB Land Pattern
Design efforts, see Intersil Technical Brief TB389.
8. COMPLIANT TO JEDEC MO-229-WEED-3 except for dimensions E2 &
D2.
For additional products, see www.intersil.com/en/products.html
Intersil products are manufactured, assembled and tested utilizing ISO9001 quality systems as noted
in the quality certifications found at www.intersil.com/en/support/qualandreliability.html
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time
without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be
accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third
parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
Submit Document Feedback
9
FN6555.2
July 15, 2014