Absolute Maximum Ratings
Supply Voltage, VPWR . . . . . . . . . . . . . . . . . . . . . . . . . GND - 0.3V to + 105V
AUXIN, VSW_FB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND - 0.3V to + 40V
COMPB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND - 0.3V to + 30V
VSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND - 0.3V to + 25V
All Others . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND - 0.3V to + 6.0V
Operating Conditions
Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40°C to +105°C
Supply Voltage Range (Typical). . . . . . . . . . . . . . . . . . . . . 18VDC to 80VDC
Thermal Information
Thermal Resistance (Typical)
JA (°C/W) JC (°C/W)
9 Ld DFN (Notes 4, 5). . . . . . . . . . . . . . . . . .
54
2.8
Maximum Junction Temperature . . . . . . . . . . . . . . . . . . . -55°C to +150°C
Maximum Storage Temperature Range . . . . . . . . . . . . . -65°C to +150°C
Pb-Free Reflow Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
NOTES:
4. JA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
5. For JC, the “case temp” location is the center of the exposed metal pad on the package underside.
6. All voltages are with respect to GND.
Electrical Specifications Recommended operating conditions unless otherwise noted. Refer to “Functional Block Diagram” on page 2
and “Typical Application” on page 3. 17V < VPWR < 100V, CVSW = 1µF, IVSW = -3mA, VSW Enabled, TA = -40°C to +105°C (Note 7), Typical values are at
TA = +25°C.
PARAMETER
TEST CONDITIONS
MIN
MAX
(Note 8)
TYP
(Note 8)
UNITS
SUPPLY VOLTAGE (VPWR)
Supply Voltage
100
V
Start-Up Current (IVPWR)
Operating Current (IVPWR)
VPWR = 12V
VSW Enabled, VPWR = 100V, VSW = 10V, 20V,
IVPWR - IVSW
VSW Disabled, VPWR = 100V,
250
450
µA
1.1
2.0
mA
1.1
2.0
mA
UVLO START Threshold
AUXIN Biased at 40V, VSW Enabled,
VPWR = 100V, VSW = 10V, 20V,
IVSW = -100mA
VSW Disabled
1.1
2.0
mA
13.0
16.5
V
UVLO STOP Threshold
VSW Disabled
12.0
15.0
V
Hysteresis
UVLO START - UVLO STOP
0.8
1.2
1.7
V
AUXILIARY VOLTAGE (AUXIN)
Maximum Bias
VPWR = 17V, 100V
40
V
OUTPUT VOLTAGE (VSW)
Load Capacitance Range
(Note 9)
0.47
1.0
1.5
µF
Overall Accuracy
Setpoint Range
VPWR = 18V, 100V, VSW = 5V, 10V, 12V
AUXIN = 15V, IVSW = -3mA to -100mA
VPWR = 100V, AUXIN = 30V
-5
1.55
+5
%
20
V
Reference
VSW_FB = VSW
1.45
1.50
1.55
V
Source Voltage Headroom (AUXIN - VSW)
VPWR = 17V, VSW = 10V, IAUXIN = 0.95*IVSW
IVSW = -100mA
IVSW = -50mA
1.8
3.0
V
1.4
2.0
V
Submit Document Feedback
4
FN6555.2
July 15, 2014