HC-5509B3999-003 Datasheet, PDF (9/10 Pages) Intersil Corporation – SLIC Subscriber Line Interface Circuit
HC-5509B3999-003
Applications Diagram
RS1 CS1
+5V
K2
+5V
K1
TIP
K1A
RB1
RB2
SECONDARY
PROTECTION
(NOTE 3)
C5
VB-
PRIMARY
PROTECTION
KIB
RS2
CS2
RING
RB3
PTC
Z1
VRING RB4
150VPEAK (MAX)
SYSTEM CONTROLLER
SHD GKD PRI RS TEST F1 ALARM F0
RD
PR
ILIMIT
TIP
VRX+
VFB
SLIC
HC-5509B3999-003
VTX
-IN1
RFS
OUT1
RING
VB- BG C2 DG AG VB+ C1
C3
C4
+5V
RL1
CAC
KRF
KZ0
RL2
FROM PCM
FILTER/CODER
TO HYBRID
BALANCE
NETWORK
FIGURE 1. TYPICAL LINE CIRCUIT APPLICATION WITH THE MONOLITHIC SLIC
TYPICAL COMPONENT VALUES
C1 = 0.5µF, 30V
C2 = 0.5µF-1.0µF ±10%, 20V (Should be nonpolarized)
C3 = 0.01µF, 100V, ±20%
C4 = 0.01µF, 100V, ±20%
C5 = 0.01µF, 100V, ±20%
CAC = 0.5µF, 20V
KZ0 = 60kΩ, (Z0 = 600Ω, K = Scaling Factor = 100)
RL1, RL2; Current Limit Setting Resistors:
RL1 + RL2 > 90kΩ → offset
ILIMIT = (0.6) (RL1 + RL2)/(200 x RL2), RL1 typically 100kΩ
KRF = 20kΩ, RF = 2(RB2 + RB4), K = Scaling Factor = 100)
RB1 = RB2 = RB3 = RB4 = 50Ω (1% absolute, matching
requirements covered in a Tech Brief)
RS1 = RS2 = 1kΩ typically
CS1 = CS2 = 0.1µF, 200V typically, depending on VRing and
line length.
Z1 = 150V to 200V transient protector. PTC used as ring
generator ballast.
NOTES:
1. All grounds (AG, BG, & DG) must be applied before VB+ or VB-. Failure to do so may result in premature failure of the part. If a user wishes to
run separate grounds off a line card, the AG must be applied first.
2. Application shows Ring Injected Ringing, a Balanced or Tip injected configuration may be used.
3. Secondary protection diode bridge recommended is 3A, 200V type.
Additional information is contained in Application Note 549, “The HC-550X Telephone SLICs” By Geoff Phillips