English
Language : 

X9315_09 Datasheet, PDF (7/16 Pages) Intersil Corporation – Digitally Controlled Potentiometer (XDCP™)
X9315
DC Electrical Specifications (Over recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
(Note 9)
VCC Supply Voltage
X9315
4.5
X9315-2.7
2.7
ICC1
ICC2
ISB
VCC active current (Increment)
CS = VIL, U/D = VIL or VIH and INC = 0.4V
@ max. tCYC
VCC active current (Store) (EEPROM CS = VIH, U/D = VIL or VIH and INC = VIH @
Store)
max. tWR
Standby supply current
CS = VCC - 0.3V, U/D and INC = VSS or VCC
- 0.3V
ILI
CS, INC, U/D input leakage current VIN = VSS to VCC
-10
VIH
CS, INC, U/D input HIGH voltage
VCC x 0.7
VIL
CS, INC, U/D input LOW voltage
-0.5
CIN CS, INC, U/D input capacitance
VCC = 5V, VIN = VSS, TA = +25°C, f = 1MHz
LIMITS
TYP
(Note 8)
10
MAX
(Note 9)
5.5
5.5
80
400
5
+10
VCC + 0.5
VCC x 0.1
UNIT
V
V
µA
µA
µA
µA
V
V
pF
Endurance and Data Retention
PARAMETER
Minimum endurance
Data retention
MIN
100,000
100
UNIT
Data changes per bit
Years
Test Circuit #1
Test Circuit #2
Circuit #3 SPICE Macro Model
VH/RH
VS
Test Point
VW/RW
VL/RL
VH/RH
Test Point
VWW/RW
VVLL/RL
Force
Current
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
RW
AC Conditions of Test
Input pulse levels
Input rise and fall times
Input reference levels
0V to 3V
10ns
1.5V
AC Electrical Specifications (Over recommended operating conditions unless otherwise specified)
LIMITS
SYMBOL
PARAMETER
MIN
(Note 9)
TYP
(Note 8)
tCl
CS to INC setup
100
tlD
INC HIGH to U/D change
100
tDI
U/D to INC setup
2.9
tlL
INC LOW period
1
tlH
INC HIGH period
1
MAX
(Note 9)
7
UNIT
ns
ns
µs
µs
µs
FN8179.2
December 21, 2009