English
Language : 

X9315_09 Datasheet, PDF (6/16 Pages) Intersil Corporation – Digitally Controlled Potentiometer (XDCP™)
X9315
Absolute Maximum Ratings
Temperature under bias . . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on CS, INC, U/D, VH, VL and
VCC with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
ΔV = |VH–VL| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V
IW (10 seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±7.5mA
Thermal Information
Thermal Resistance (Typical, Notes 3, 4) θJA (°C/W) θJC (°C/W)
8 Ld SOIC . . . . . . . . . . . . . . . . . . . . . . 105
68
8 Ld MSOP. . . . . . . . . . . . . . . . . . . . . . 154
58
8 Ld PDIP. . . . . . . . . . . . . . . . . . . . . . .
85
57
Pb-Free Reflow Profile. . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Recommended Operating Conditions
Temperature (Commercial) . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Temperature (Industrial). . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage (VCC) (Note 8) Limits
X9315. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V ± 10%
X9315-2.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Max Wiper Current, IW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3.75mA
Max Power Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10mW
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTES:
3. θJA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
4. For θJC, the “case temp” location is taken at the package top center.
Potentiometer Characteristics (Over recommended operating conditions unless otherwise stated.)
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS/NOTES
MIN
TYP
MAX
(Note 9) (Note 8) (Note 9) UNIT
End to end resistance tolerance
-20
+20
%
VVH
VH terminal voltage
VVL
VL terminal voltage
RW
Wiper resistance
RW
Wiper resistance
Noise
0
0
IW = [V(RH) - V(RL)]/ RTOTAL, VCC = 5V
IW = [V(RH) - V(RL)]/ RTOTAL, VCC = 2.7V
Ref: 1kHz
VCC
V
VCC
V
200
400
Ω
400
1000
Ω
-120
dBV
Resolution
3
%
Absolute linearity (Note 5)
Vw(n)(actual) - Vw(n)(expected)
±1
MI
(Note 7)
Relative linearity (Note 6)
Vw(n + 1) - [Vw(n) + MI]
±0.2
MI
(Note 7)
RTOTAL temperature coefficient
Ratiometric temperature coefficient
±300
±20
ppm/°C
ppm/°C
CH/CL/CW Potentiometer capacitances
See circuit #3 on page 7
10/10/25
pF
NOTES:
5. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage = (Vw(n)(actual) - Vw(n)(expected)) = ±1 Ml Maximum.
6. Relative linearity is a measure of the error in step size between taps = RW(n+1) - [Rw(n) + Ml] = ±0.2 Ml.
7. 1 Ml = Minimum Increment = RTOT/31.
8. Typical values are for TA = +25°C and nominal supply voltage.
9. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by
characterization and are not production tested.
6
FN8179.2
December 21, 2009