ISL5120 Datasheet, PDF (7/15 Pages) Intersil Corporation – Low-Voltage, Single Supply, Dual SPST, SPDT Analog Switches | |||
|
◁ |
ISL5120, ISL5121, ISL5122, ISL5123
Electrical Specifications - 12V Supply
Test Conditions: V+ = +10.8V to +13.2V, GND = 0V, VINH = 4V, VINL = 0.8V (Note 5),
Unless Otherwise Specified (Continued)
PARAMETER
TEST CONDITIONS
TEMP (NOTE 6)
(°C)
MIN
(NOTE 6)
TYP
MAX UNITS
COM ON Leakage Current,
ICOM(ON)
V+ = 13V, VCOM = 1V, 12V, or VNO or VNC = 1V, 12V, 25
-0.2
-
0.2
nA
or floating, (Note 7)
Full
-10
-
10
nA
DYNAMIC CHARACTERISTICS
Turn-ON Time, tON
VNO or VNC = 10V, RL =1kâ¦, CL = 35pF, VIN = 0 to 4V 25
-
Full
-
25
35
ns
35
55
ns
Turn-OFF Time, tOFF
VNO or VNC = 10V, RL =1kâ¦, CL = 35pF, VIN = 0 to 4V 25
-
Full
-
17
30
ns
26
50
ns
Break-Before-Make Time Delay
(ISL5122, ISL5123), tD
Charge Injection, Q
OFF Isolation
Crosstalk (Channel-to-Channel)
RL = 300â¦, CL = 35pF, VNO or VNC = 10V,
VIN = 0 to 4V
CL = 1.0nF, VG = 0V, RG = 0â¦
RL = 50â¦, CL = 5pF, f = 1MHz
Full
0
2
ns
25
-
5
15
pC
25
-
76
-
dB
25
-
-105
-
dB
Power Supply Rejection Ratio
RL = 50â¦, CL = 5pF, f = 1MHz
25
-
63
-
dB
NO or NC OFF Capacitance, COFF f = 1MHz, VNO or VNC = VCOM = 0V
25
-
8
-
pF
COM OFF Capacitance,
CCOM(OFF)
f = 1MHz, VNO or VNC = VCOM = 0V
25
-
8
-
pF
COM ON Capacitance, CCOM(ON) f = 1MHz, VNO or VNC = VCOM = 0V, ISL5120/1/2
25
-
21
-
pF
f = 1MHz, VNO or VNC = VCOM = 0V, ISL5123
25
-
28
-
pF
POWER SUPPLY CHARACTERISTICS
Positive Supply Current, I+
V+ = 13V, VIN = 0V or V+, all channels on or off
DIGITAL INPUT CHARACTERISTICS
Full
-1
-
1
µA
Input Voltage Low, VINL
Input Voltage High, VINH
Input Voltage High, VINH
Input Current, IINH, IINL
ISL5120CX only
V+ = 13V, VIN = 0V or V+
Full
-
-
0.8
V
Full
2.9
-
-
V
Full
4
3
-
V
Full
-1
-
1
µA
Test Circuits and Waveforms
3V OR 4V
LOGIC
INPUT
0V
SWITCH
INPUT
VNO
SWITCH
OUTPUT 0V
50%
tOFF
VOUT
90%
tON
tr < 20ns
tf < 20ns
90%
V+
C
SWITCH
INPUT
LOGIC
INPUT
NO or NC
IN
GND
COM
VOUT
RL
CL
1k⦠35pF
Logic input waveform is inverted for switches that have the opposite
logic sense.
FIGURE 1A. MEASUREMENT POINTS
Repeat test for all switches. CL includes fixture and stray
capacitance.
VOUT
=
V(NO or NC)
------------R-----L-------------
RL + R(ON)
FIGURE 1B. TEST CIRCUIT
FIGURE 1. SWITCHING TIMES
7
FN6022.6
November 17, 2004
|
▷ |