English
Language : 

X93256 Datasheet, PDF (6/9 Pages) Intersil Corporation – Dual Digitally Controlled Potentiometers
X93256
A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Symbol
tCl
tlD
tDI
tlL
tlH
tlC
tCPH
tCPH
tCYC
tR, tF(6)
tR VCC(6)
tWR
Parameter
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC Inactive to CS inactive
CS Deselect time (NO STORE)
CS Deselect time (STORE)
INC cycle time
INC input rise and fall time
VCC power-up rate
Store cycle
Min.
100
100
100
1
1
1
250
10
2
0.2
Limits
Typ.(6)
Max.
500
10,000
5
10
Unit
ns
ns
ns
µs
µs
µs
ns
ms
µs
µs
V/ms
ms
POWER UP AND DOWN REQUIREMENTS
There are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the potentiometer
pins provided that VCC is always more positive than or equal to VH and VL, i.e., VCC ≥ VH,VL. The VCC ramp rate spec is
always in effect.
A.C. TIMING
CS
tCI
INC
U/D
tCYC
tIL
tIH
tIC
tID
tDI
(Store)
tCPH
90% 90%
10%
tF
tR
6
FN8188.0
March 4, 2005