AC Electrical Specifications (Over recommended operating conditions unless otherwise specified)
SYMBOL
PARAMETER
LIMITS
MIN
TYP(4)
tCl
tlD
tDI
tlL
tlH
tlC
tCPH
tIW
tCYC
tR, tF(5)
tPU(5)
tR VCC
CS to INC Setup
INC HIGH to U/D Change
U/D to INC Setup
INC LOW Period
INC HIGH Period
INC Inactive to CS Inactive
CS Deselect Time
INC to VW Change
INC Cycle Time
INC Input Rise and Fall Time
Power-up to Wiper Stable
VCC Power-up Rate
100
100
2.9
1
1
1
20
100
4
0.2
A.C. Timing
MAX
500
500
500
50
UNITS
ns
ns
µs
µs
µs
µs
ms
µs
µs
µs
µs
mV/µs
CS
tCYC
tIL
tIH
tCI
INC
tIC
tCPH
90% 90%
10%
tID tDI
U/D
tF
tR
tIW
VW
MI (6)
NOTES:
4. Typical values are for TA = +25°C and nominal supply voltage.
5. This parameter is periodically sampled and not 100% tested.
6. MI in the A.C. timing diagram refers to the minimum incremental change in the VW output due to a change in the wiper position.
6
FN8178.2