English
Language : 

ISL78215 Datasheet, PDF (6/11 Pages) Intersil Corporation – Improved Industry Standard Single-Ended Current Mode PWM Controller
ISL78215
Absolute Maximum Ratings
Supply Voltage, VDD . . . . . . . . . . . . . GND - 0.3V to +20.0V
OUT . . . . . . . . . . . . . . . . . . . . . GND - 0.3V to VDD + 0.3V
Signal Pins . . . . . . . . . . . . . . . . . . . . . GND - 0.3V to 6.0V
Peak GATE Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1A
ESD Rating
Human Body Model (Tested per JESD22-A11) . . . . . 2500V
Machine Model (Tested per JESD22-C101) . . . . . . . . . 75V
Charged Device Model (Tested per JESD22-A115) . . 1500V
Thermal Information
Thermal Resistance (Typical)
θJA (°C/W) θJC (°C/W)
MSOP Package (Notes 4, 5) . . . . . . 170
60
Maximum Junction Temperature . . . . . . . . -55°C to +150°C
Maximum Storage Temperature Range . . . -65°C to +150°C
Pb-Free Reflow Profile . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Operating Conditions
Temperature Range . . . . . . . . . . . . . . . . . -40°C to +105°C
Supply Voltage Range (Typical, Note 6). . . . . . . .7.5V to 18V
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact
product reliability and result in failures not covered by warranty.
NOTES:
4. θJA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief
TB379 for details.
5. For θJC, the “case temp” location is taken at the package top center.
6. All voltages are with respect to GND.
Electrical Specifications
Recommended operating conditions unless otherwise noted. Refer to “Functional Block
Diagram” on page 3 and “Typical Application” schematics on page 4 and 5. VDD = 15V
(Note 10), Rt = 10kΩ, Ct = 3.3nF, TA = -40 to +105°C, Typical values are at
TA = +25°C. Boldface limits apply over the operating temperature range, -40°C to
+105°C.
PARAMETER
TEST CONDITIONS
MIN
(Note 7)
TYP
MAX
(Note 7)
UNITS
UNDERVOLTAGE LOCKOUT
START Threshold
6.5
7.0
7.5
V
STOP Threshold
6.1
6.6
6.9
V
Hysteresis
-
0.4
-
V
Start-up Current, IDD
Operating Current, IDD
Operating Supply Current, ID
REFERENCE VOLTAGE
VDD < START Threshold
(Note 8)
Includes 1nF GATE loading
-
60
100
µA
-
3.3
4.0
mA
-
4.1
5.5
mA
Overall Accuracy
Over line (VDD = 12V to 18V),
4.925
5.000
5.050
V
load, temperature
Long Term Stability
TA = +125°C, 1000 hours
(Note 9)
-
5
-
mV
Fault Voltage
4.40
4.65
4.85
V
VREF Good Voltage
4.60
4.80 VREF - 0.05
V
Hysteresis
50
165
250
mV
Current Limit, Sourcing
-20
-
-
mA
Current Limit, Sinking
5
-
-
mA
CURRENT SENSE
Input Bias Current
CS Offset Voltage
COMP to PWM Comparator Offset
Voltage
VCS = 1V
VCS = 0V (Note 9)
VCS = 0V (Note 9)
-1.0
-
1.0
µA
95
100
105
mV
0.80
1.15
1.30
V
Input Signal, Maximum
0.91
0.97
1.03
V
Gain, ACS = ΔVCOMP/ΔVCS
0 < VCS < 910mV, VFB = 0V
2.5
3.0
3.5
V/V
(Note 9)
6
FN7673.0
August 16, 2010