English
Language : 

HCTS160MS Datasheet, PDF (6/9 Pages) Intersil Corporation – Radiation Hardened Synchronous Counter
Specifications HCTS160MS
TABLE 6. APPLICABLE SUBGROUPS
CONFORMANCE GROUPS
METHOD
GROUP A SUBGROUPS
Initial Test (Preburn-In)
100%/5004
1, 7, 9
Interim Test I (Postburn-In)
100%/5004
1, 7, 9
Interim Test II (Postburn-In)
100%/5004
1, 7, 9
PDA
100%/5004
1, 7, 9, Deltas
Interim Test III (Postburn-In)
100%/5004
1, 7, 9
PDA
100%/5004
1, 7, 9, Deltas
Final Test
100%/5004
2, 3, 8A, 8B, 10, 11
Group A (Note 1)
Sample/5005
1, 2, 3, 7, 8A, 8B, 9, 10, 11
Group B
Subgroup B-5
Sample/5005 1, 2, 3, 7, 8A, 8B, 9, 10, 11, Deltas
Subgroup B-6
Sample/5005
1, 7, 9
Group D
Sample/6005
1, 7, 9
NOTE:
1. Alternate Group A testing in accordance with Method 5005 of Mil-Std-883 may be exercised.
READ AND RECORD
ICC, IOL/H
ICC, IOL/H
ICC, IOL/H
Subgroups 1, 2, 3, 9, 10, 11
TABLE 7. TOTAL DOSE IRRADIATION
CONFORMANCE
GROUPS
METHOD
TEST
PRE RAD
POST RAD
Group E Subgroup 2
5005
1, 7, 9
Table 4
NOTE:
1. Except FN test which will be performed 100% go/no-go.
READ AND RECORD
PRE RAD
POST RAD
1, 9
Table 4 (Note 1)
TABLE 8. STATIC AND DYNAMIC BURN-IN TEST CONNECTIONS
OPEN
GROUND
1/2 VCC = 3V ± 0.5V
VCC = 6V ± 0.5V
STATIC I BURN-IN
11 - 15
1 - 10
-
16
STATIC II BURN-IN
11 - 15
8
-
1 - 7, 9, 10, 16
DYNAMIC BURN-IN
-
4, 6, 8
11 - 15
1, 3, 5, 7, 9, 10, 16
NOTES:
1. Each pin except VCC and GND will have a resistor of 10KΩ ± 5% for static burn-in
2. Each pin except VCC and GND will have a resistor of 1KΩ ± 5% for dynamic burn-in
OSCILLATOR
50kHz
25kHz
-
-
-
-
2
-
TABLE 9. IRRADIATION TEST CONNECTIONS
OPEN
GROUND
VCC = 5V ± 0.5V
11 - 15
8
1 - 7, 9, 10, 16
NOTE: Each pin except VCC and GND will have a resistor of 47KΩ ± 5% for irradiation testing.
Group E, Subgroup 2, sample size is 4 dice/wafer 0 failures.
Spec Number 518611
565