X9252
DC Electrical Specifications Over the recommended operating conditions unless otherwise specified. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
MAX
UNITS
IL
Leakage current, bus interface pins
VIH
Input HIGH voltage
VIL
Input LOW voltage
VOL
SDA pin output LOW voltage
Voltage at pin from VSS to VCC
IOL = 3mA
-10
10
µA
VCC x 0.7 VCC + 1
V
-1
VCC x 0.3
V
0.4
V
Endurance and Data Retention
PARAMETER
Minimum endurance
Data retention
MIN
100,000
100
UNITS
Data changes per bit
Years
Capacitance
Symbol
Test
CIN/OUT (Note 5) Input / Output capacitance (SDA)
CIN (Note 5) Input capacitance (SCL, WP, DS0, DS1, CS, U/D, A2, A1 and
A0)
Test Conditions
VOUT = 0V
VIN = 0V
Max.
8
6
Units
pF
pF
Power-Up Timing
SYMBOL
PARAMETER
tD (Notes 5, 9) Power Up Delay from VCC power up (VCC above 2.7V) to wiper position recall
completed, and communication interfaces ready for operation.
MAX
2
UNITS
ms
A.C. Test Conditions
Input Pulse Levels
Input rise and fall times
Input and output timing threshold level
External load at pin SDA
2-Wire Interface timing (s)
SYMBOL
PARAMETER
fSCL
tHIGH
tLOW
tSU:STA
tHD:STA
tSU:STO
tSU:DAT
tHD:DAT
tR (Note 5)
tF (Note 5)
tAA (Note 5)
tDH
tIN (Note 5)
Clock Frequency
Clock High Time
Clock Low Time
Start Condition Setup Time
Start Condition Hold Time
Stop Condition Setup Time
SDA Data Input Setup Time
SDA Data Input Hold Time
SCL and SDA Rise Time
SCL and SDA Fall Time
SCL Low to SDA Data Output Valid Time
SDA Data Output Hold Time
Pulse Width Suppression Time at SCL and SDA inputs
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
2.3kΩ to VCC and 100pF to VSS
MIN
600
1300
600
600
600
100
30
0
MAX
400
300
300
0.9
50
UNITS
kHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
µs
ns
ns
5
FN8167.1