Electrical Specifications (X60003-50) VIN = 6.5V, TA = -40°C to +85°C, unless otherwise specified. Boldface limits apply over
the operating temperature range, -40°C to +85°C.
SYMBOL
PARAMETER
CONDITIONS
MIN
MAX
(Note 12) TYP (Note 12) UNITS
VIN
Input Voltage Range
5.1
9.0
V
VOUT
Output Voltage
5.000
V
VOUT/VIN Line Regulation
+5.5V  VIN  +8.0V
150
µV/V
VOUT/IOUT Load Regulation
Sourcing: 0mA ISOURCE  10mA
10
50
µV/mA
Sinking: -10mA  ISINK  0mA
20
100
µV/mA
VDO
Dropout Voltage
IOUT = 5mA, VOUT = -0.01%
150
300
mV
VOUT/TA Thermal Hysteresis (Note 10)
T = -40°C to +85°C
100
ppm
VOUT/t
Long Term Stability (Note 11)
TA = +25°C
45
ppm
NOTES:
9. Over the specified temperature range. Temperature coefficient is measured by the box method whereby the change in VOUT is divided by the
temperature range; in this case, -40°C to +85°C = +125°C.
10. Thermal Hysteresis is the change of VOUT measured at TA = +25°C after temperature cycling over a specified range, TA. VOUT is read initially at
TA = +25°C for the device under test. The device is temperature cycled and a second VOUT measurement is taken at +25°C. The difference between
the initial VOUT reading and the second VOUT reading is then expressed in ppm. For  TA = +125°C, the device under test is cycled from +25°C to
+85°C to -40°C to +85°C.
11. Long term drift is logarithmic in nature and diminishes over time. Drift after the first 1000 hours will be approximately 10ppm/sqrt(1kHrs).
12. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization
and are not production tested.