Absolute Voltage Ratings
Max Voltage Applied
VIN to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to +10V
VOUT to GND (10s). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to +5.1V
ESD Ratings
Human Body Model (Tested to JESD22-A114) . . . . . . . . . . . . . . . . . . 5kV
Machine Model (Tested to JESD22-A115) . . . . . . . . . . . . . . . . . . . . . 500V
Latch Up (Tested per JESD-78B; Class 2, Level A) . . . . . . . . . . . . . . 100mA
Environmental Operating Conditions
X-Ray Exposure (Note 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10mRem
Thermal Information
Thermal Resistance (Typical)
JA (°C/W) JC (°C/W)
3 Lead SOT-23 (Notes 6, 7) . . . . . . . . . . . . . . 275
110
Maximum Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . .+107°C
Storage Temperature Range. . . . . . . . . . . . . . . . . . . . . . . .-65°C to +125°C
Pb-Free Reflow Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see TB493
Recommended Operating Conditions
Temperature Range (Industrial) . . . . . . . . . . . . . . . . . . . . . . -40°C to +85°C
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
IMPORTANT NOTE: All parameters having Min/Max specifications are guaranteed. Typ values are for information purposes only. Unless otherwise noted,
all tests are at the specified temperature and are pulsed tests, therefore: TJ = TC = TA
NOTES:
5. Measured with no filtering, distance of 10” from source, intensity set to 55kV and 70mA current, 30s duration. Other exposure levels should be
analyzed for Output Voltage drift effects. See “Applications Information” on page 12.
6. JA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
7. For JC, the “case temp” location is taken at the package top center.
8. Post-reflow drift for the X60003 devices will range from 100µV to 1.0mV based on experimental results with devices on FR4 double sided boards.
The design engineer must take this into account when considering the reference voltage after assembly.
Electrical Specifications Operating Conditions: IOUT = 0mA, COUT = 0.001µF, TA = -40 to +85°C. Boldface limits apply over
the operating temperature range, -40°C to +85°C.
SYMBOL
PARAMETER
CONDITIONS
MIN
MAX
(Note 12) TYP (Note 12)
UNITS
VOA
VOUT Accuracy @ TA = +25°C
X60003B
X60003C
-1.0
+1.0
mV
-2.5
+2.5
mV
X60003D
-5.0
+5.0
mV
IIN
TC VOUT
Supply Current
Output Voltage Temperature Coefficient
(Note 9)
X60003B
X60003C
500
900
nA
10
ppm/°C
20
ppm/°C
X60003D
20
ppm/°C
VN
Output Voltage Noise
ISC
Short Circuit Current
0.1Hz to 10Hz
TA = +25°C
30
50
80
µVP-P
mA
Electrical Specifications (X60003-41) VIN = 5.0, TA = -40°C to +85°C, unless otherwise specified. Boldface limits apply over
the operating temperature range, -40°C to +85°C.
SYMBOL
PARAMETER
CONDITIONS
MIN
MAX
(Note 12) TYP (Note 12) UNITS
VIN
VOUT
VOUT/VIN
VOUT/IOUT
Input Voltage Range
Output Voltage
Line Regulation
Load Regulation
VOUT/TA
VOUT/t
Thermal Hysteresis (Note 10)
Long Term Stability (Note 11)
+4.5V  VIN  +8.0V
Sourcing: 0mA  ISOURCE  10mA
Sinking: -10mA  ISINK  0mA
T = -40°C to +85°C
TA = +25°C
4.5
9.0
V
4.096
V
150
µV/V
10
50
µV/mA
20
100
µV/mA
150
ppm
50
ppm