English
Language : 

ISL6721ABZ-T Datasheet, PDF (5/22 Pages) Intersil Corporation – Flexible Single-ended Current Mode PWM Controller
ISL6721
Absolute Maximum Ratings
Supply Voltage, VCC, VC . . . . . . . . . . . . . . . . . GND -0.3V to +20.0V
GATE . . . . . . . . . . . . . . . . GND - 0.3V to Gate Output Limit Voltage
PGND to LGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.3V
VREF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND - 0.3V to 5.3V
Signal Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . GND - 0.3V to VREF
Peak GATE Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1A
Operating Conditions
Temperature Range
ISL6721Ax . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +105°C
Supply Voltage Range (Typical, Note 2) . . . . . . . . 9VDC to 18VDC
Thermal Information
Thermal Resistance (Typical, Note 1)
θJA (°C/W)
16 Ld SOIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
80
16 Ld TSSOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
105
Maximum Junction Temperature . . . . . . . . . . . . . . .-55°C to +150°C
Maximum Storage Temperature Range . . . . . . . . . .-65°C to +150°C
Pb-free reflow profile . . . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTES:
1. θJA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
2. All voltages are with respect to GND.
Electrical Specifications
Recommended operating conditions unless otherwise noted. Refer to Block Diagram and Typical Application
schematic on page 2 and page 3. 9V < VCC = VC < 20V, RT = 11kΩ, Ct = 330 pF, TA = -40 to +105°C (Note 3),
Typical values are at TA = +25°C.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
UNDERVOLTAGE LOCKOUT
START Threshold
7.95
8.25
8.55
V
STOP Threshold
7.40
7.70
8.20
V
Hysteresis
0.50
0.55
1.00
V
Start-Up Current, ICC
OC/OV Fault Operating Current, ICC
Operating Current, ICC
Operating Supply Current, IC
REFERENCE VOLTAGE
VCC < START Threshold
Includes 1nF GATE loading
-
100
175
µA
-
200
300
µA
-
4.5
10.0
mA
-
8.0
12.0
mA
Overall Accuracy
Line, load, 0°C to +105°C
4.95
5.00
5.05
V
Line, load, -40°C to +105°C
4.90
5.00
5.05
V
Long Term Stability
Fault Voltage
TA = +125°C, 1000 hours (Note 5)
-
5
-
mV
4.50
4.65
4.75
V
VREF Good Voltage
4.65
4.80
4.95
V
Hysteresis
75
165
250
mV
Operational Current
-10
-
-
mA
Current Limit
-20
-
-
mA
CURRENT SENSE
Input Impedance
-
5
-
kΩ
Offset Voltage
0.08
0.10
0.11
V
Input Voltage Range
0
-
1.5
V
Blanking Time
(Note 5)
30
60
100
ns
Gain, ACS
VSLOPE = 0V, VFB = 2.3V,
VISET = 0.35V, 1.5V
ACS = ΔISET/ΔISENSE
0.77
0.79
0.81
V/V
5
FN9110.6
March 5, 2008