ISL29147
I2C Electrical Specifications For SCL and SDA unless otherwise noted, VDD = 3V, TA = +25°C (Note 8). (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
(Note 10)
MAX
TYP (Note 10) UNITS
tSU:DAT Data Set-up Time
100
ns
tR
Rise Time of both SDA and SCL Signals
(Note 9)
20 + 0.1 x Cb
ns
tF
Fall Time of both SDA and SCL Signals
(Note 9)
20 + 0.1 x Cb
ns
tSU:STO Set-up Time for STOP Condition
600
ns
tBUF
Bus Free Time Between a STOP and START Condition
1300
ns
Cb
Capacitive Load for Each Bus Line
400
pF
Rpull-up SDA and SCL System Bus Pull-Up Resistor
Maximum determined by tR and tF
1
kΩ
tVD;DAT Data Valid Time
0.9
µs
tVD:ACK Data Valid Acknowledge Time
0.9
µs
VnL
Noise Margin at the LOW Level
0.1VDD
V
VnH
Noise Margin at the HIGH Level
0.2VDD
V
NOTES:
6. Cover glass assumes fixed infrared/visible light transmissivity ratio of 10.
7. An 850nm infrared LED is used in production test for proximity/IR sensitivity testing.
8. All parameters in the I2C Electrical Specifications table are guaranteed by design and simulation.
9. Cb is the capacitance of the bus in pF.
10. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization