Operating Specifications Over the recommended operating conditions unless otherwise specified. Parameters with MIN and/or MAX
limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization
and are not production tested. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
TYP
MIN (Note 3) MAX
UNIT
VIH
SHDN, SCK, SDI, and CS input buffer
HIGH voltage
0.7*VCC
VCC+0.3
V
Hysteresis SHDN, SCK, SDI, and CS input buffer
hysteresis
VOL
Rpu
(Note 12)
SDO output buffer LOW voltage
SDO pull-up resistor off-chip
IOL = 4mA
Maximum is determined by tRO and tFO with
maximum bus load Cbus = 30pF, fSCK =
5MHz
0.05*
VCC
0
V
0.4
V
2
kΩ
Cpin SHDN, SCK, SDI, SDO and CS pin
(Note 13) capacitance
10
pF
fSCK
tCYC
tWH
tWL
tLEAD
tLAG
tSU
tH
tRI
tFI
tDIS
tV
tHO
tRO
tFO
tCS
tWRT
SPI frequency
SPI clock cycle time
SPI clock high time
SPI clock low time
Lead time
Lag time
SDI, SCK and CS input setup time
SDI, SCK and CS input hold time
SDI, SCK and CS input rise time
SDI, SCK and CS input fall time
SDO output Disable time
SDO output valid time
SDO output hold time
SDO output rise time
SDO output fall time
CS deselect time
Rpu = 2k, Cbus = 30pF
Rpu = 2k, Cbus = 30pF
Wiper Response Time after SPI write
to WR register
5
MHz
200
ns
100
ns
100
ns
250
ns
250
ns
50
ns
50
ns
10
ns
10
20
ns
0
100
ns
350
ns
0
ns
60
ns
60
ns
2
µs
1.5
µs
NOTES:
3. Typical values are for TA = +25°C and 3.3V supply voltage.
4. LSB: [V(RW)127 – V(RW)0]/127. V(RW)127 and V(RW)0 are V(RW) for the DCP register set to 7F hex and 00 hex respectively. LSB is the
incremental voltage when changing from one tap to an adjacent tap.
5. ZS error = V(RW)0/LSB.
6. FS error = [V(RW)127 – VCC]/LSB.
7. DNL = [V(RW)i – V(RW)i-1]/LSB-1, for i = 1 to 127. i is the DCP register setting.
8. INL = [V(RW)i – i • LSB – V(RW)]/LSB for i = 1 to 127
9. VMATCH = [V(RWx)i – V(RWy)i]/LSB, for i = 1 to 127, x = 0 to 3 and y = 0 to 3.
10.
TCV
=
-------M-----a----x----(--V----(---R-----W------)--i--)---–-----M-----i--n----(--V-----(--R-----W------)--i--)------ × ----1---0----6----- for i = 16 to 112 decimal, T = -40°C to +125°C. Max( ) is the maximum value of the wiper
[Max(V(RW)i) + Min(V(RW)i)] ⁄ 2 165°C voltage and Min ( ) is the minimum value of the wiper voltage over the temperature range.
11. tWC is the time from the end of a Write sequence of SPI serial interface, to the end of the self-timed internal non-volatile write cycle.
12. Rpu is specified for the highest data rate transfer for the device. Higher value pullup can be used at lower data rates.
13. This parameter is not 100% tested.