TABLE 3. ELECTRICAL PERFORMANCE CHARACTERISTICS
Device Characterized at: VSUPPLY = ±5V, AV = +2, RF = 681Ω, RL = 400Ω, Unless Otherwise Specified.
LIMITS
PARAMETERS
SYMBOL
CONDITIONS
NOTES TEMPERATURE MIN MAX UNITS
-3dB Bandwidth
Gain Flatness
Slew Rate
Rise and Fall Time
Overshoot
Propagation Delay
BW(+1) AV = +1, RF = 1K
1
VOUT = 100mVRMS
BW(+2) AV = +2,
1
VOUT = 100mVRMS
GF5
AV = +2, f ≤5MHz
1
VOUT = 100mVRMS
GF10 AV = +2, f ≤10MHz
1
VOUT = 100mVRMS
GF20 AV = +2, f ≤20MHz
1
VOUT = 100mVRMS
+SR(+1) AV = +1, RF = 1K
1, 4
VOUT = -2V to +2V
-SR(+1) AV = +1, RF = 1K
1, 4
VOUT = +2V to -2V
+SR(+2) AV = +2, VOUT = -2V to +2V
1, 4
-SR(+2) AV = +2, VOUT = +2V to -2V
1, 4
TR
AV = +2, VOUT = -0.5V to +0.5V
1, 2
TF
AV = +2, VOUT = +0.5V to -0.5V
1, 2
+OS
AV = +2, VOUT = -0.5V to +0.5V
1, 3
-OS
AV = +2, VOUT = +0.5V to -0.5V
1, 3
+TP
AV = +2, RF = 681Ω
1, 2
VOUT = 0V to 1V
-TP
AV = +2, RF = 681Ω
1, 2
VOUT = 1V to 0V
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
+125oC, -55oC
62
-
MHz
62
-
MHz
-
±0.045
dB
-
±0.085
dB
-
±0.65
dB
250
-
V/µs
240
-
V/µs
400
-
V/µs
360
-
V/µs
-
6.5
ns
-
6.5
ns
-
35
%
-
27
%
-
9.5
ns
-
9.0
ns
NOTES:
1. Parameters listed in Table 3 are controlled via design or process parameters and are not directly tested at final production. These param-
eters are lab characterized upon initial design release, or upon design changes. These parameters are guaranteed by characterization
based upon data from multiple production runs which reflect lot-to-lot and within lot variation.
2. Measured between 10% and 90% points.
3. For 200ps input transition times. Overshoot decreases as input transition times increase, especially for AV = +1. Please refer to
Performance Curves.
4. Measured between 25% and 75% points.
TABLE 4. ELECTRICAL TEST REQUIREMENTS
MIL-STD-883 TEST REQUIREMENTS
SUBGROUPS (SEE TABLE 1)
Interim Electrical Parameters (Pre Burn-In)
Final Electrical Test Parameters
Group A Test Requirements
1
1 (Note 1), 2, 3, 4
1, 2, 3, 4
Groups C and D Endpoints
1
NOTE:
1. PDA applies to Subgroup 1 only.
Spec Number 511108-883
4